AI Article Synopsis

  • Project Aquafluosense aims to create prototypes for measuring water quality parameters using fluorescence-based instruments, specifically focusing on detecting environmental pollutants like mycotoxin zearalenone (ZON).
  • The project has developed an enzyme-linked fluorescent immunoassay (ELFIA) that can detect ZON in concentrations as low as 0.09 ng/mL, outperforming traditional methods in sensitivity.
  • The ELFIA method is not only effective for ZON detection but also versatile, enabling in situ analysis of other water quality metrics such as organic carbon content and algal density through induced fluorimetry.

Article Abstract

Project Aquafluosense is designed to develop prototypes for a fluorescence-based instrumentation setup for in situ measurements of several characteristic parameters of water quality. In the scope of the project an enzyme-linked fluorescent immunoassay (ELFIA) method has been developed for the detection of several environmental xenobiotics, including mycotoxin zearalenone (ZON). ZON, produced by several plant pathogenic species, has recently been identified as an emerging pollutant in surface water, presenting a hazard to aquatic ecosystems. Due to its physico-chemical properties, detection of ZON at low concentrations in surface water is a challenging task. The 96-well microplate-based fluorescence instrument is capable of detecting ZON in the concentration range of 0.09-400 ng/mL. The sensitivity and accuracy of the analytical method has been demonstrated by a comparative assessment with detection by high-performance liquid chromatography and by total internal reflection ellipsometry. The limit of detection of the method, 0.09 ng/mL, falls in the low range compared to the other reported immunoassays, but the main advantage of this ELFIA method is its efficacy in combined in situ applications for determination of various important water quality parameters detectable by induced fluorimerty-e.g., total organic carbon content, algal density or the level of other organic micropollutants detectable by immunofluorimetry. In addition, the immunofluorescence module can readily be expanded to other target analytes if proper antibodies are available for detection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8000975PMC
http://dx.doi.org/10.3390/toxins13030182DOI Listing

Publication Analysis

Top Keywords

mycotoxin zearalenone
8
water quality
8
elfia method
8
surface water
8
water
5
detection
5
development immunofluorescence
4
immunofluorescence assay
4
assay module
4
module determination
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!