Both acute and chronic ingestion of 2S-hesperidin have shown antioxidant and anti-inflammatory effects in animal studies, but so far, no one has studied this effect of chronic ingestion in humans. The main objective was to evaluate whether an 8-week intake of 2S-hesperidin had the ability to modulate antioxidant-oxidant and inflammatory status in amateur cyclists. A parallel, randomized, double-blind, placebo-controlled trial study was carried out with two groups (500 mg/d 2S-hesperidin; = 20 and 500 mg/d placebo; = 20). An incremental test was performed to determine the working zones in a rectangular test, which was used to analyze for changes in antioxidant and inflammatory biomarkers. After 2S-hesperidin ingestion, we found in the rectangular test: (1) an increase in superoxide dismutase (SOD) after the exercise phase until exhaustion ( = 0.045) and the acute recovery phase ( = 0.004), (2) a decrease in the area under the oxidized glutathione curve (GSSG) ( = 0.016), and (3) a decrease in monocyte chemoattractant protein 1 (MCP1) after the acute recovery phase ( = 0.004), post-intervention. Chronic 2S-hesperidin supplementation increased endogenous antioxidant capacity (↑SOD) after maximal effort and decreased oxidative stress (↓AUC-GSSG) during the rectangular test, decreasing inflammation (↓MCP1) after the acute recovery phase.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8000657 | PMC |
http://dx.doi.org/10.3390/antiox10030432 | DOI Listing |
Sci Rep
January 2025
Department of Orthodontics, Institute of Oral Health Science, Ajou University School of Medicine, Suwon, South Korea.
Background: The demand for orthodontic treatment using clear aligners has been gradually increasing because of their superior esthetics compared with conventional fixed orthodontic therapy. This study aimed to evaluate and compare the compressive strength of three-dimensional direct printing aligners (3DPA) with that of conventional thermo-forming aligners (TFA) to determine their clinical applicability. In the experimental group, the 3DPA material TC-85 (TC-85 full) was used to create angular protrusions called rectangular pressure areas (RPA).
View Article and Find Full Text PDFJ Magn Reson
January 2025
Department of Chemistry, Seoul National University, Seoul 08826 Republic of Korea; Advanced Institutes of Convergence Technology, Suwon 16229 Republic of Korea. Electronic address:
Most NMR samples are cylindrical, which is ideal for obtaining high-resolution NMR spectra, especially in superconducting magnets with a vertical bore. However, expanding NMR applicability to samples that are not necessarily cylindrical requires a new approach. In this study, we introduce a method for obtaining solution NMR signals from flat samples, such as flat containers or layered structures like a fuel cell.
View Article and Find Full Text PDFJ Spinal Cord Med
January 2025
Department of Research, Sunnaas Rehabilitation Hospital, Bjørnemyr, Norway.
Objectives: Assess pateint-reported effects of transcutaneous spinal cord stimulation (tSCS) on spasticity after multiple treatment.
Design: An uncontrolled prospective case series study.
Setting: A rehabilitation hospital.
Sci Rep
January 2025
Department of Electrical Engineering, University of New Mexico, Albuquerque, NM, 87606, USA.
Topology optimization is a powerful technique that utilizes the distribution of material properties along with surface topology as parameters to expand a specified performance. While primarily used as a foundational step in regenerative design for structural mechanics, the general TO framework is also applicable to many of the complex issues in electromagnetics such as frequency agile mode converters. This is considered a difficult parameter to optimize since RF components operate on resonance.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Centre for Interdisciplinary Research in Rehabilitation and Social Integration, Quebec City, QC G1M 2S8, Canada.
Although guidelines are established for performing the six-minute walking test (6MWT), it is not always possible to implement this test in any setting, due to physical and space limitations. Yet, variations in the conditions of the test could be responsible for heterogeneous outcomes. However, the impact of the condition of the 6MWT is not clearly established in literature.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!