A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vivo measurement of distance between scapular neck and polyethylene insert during active external rotation in shoulders with Grammont type reverse prosthesis. | LitMetric

Background: Scapular notching is a frequently observed complication after reverse shoulder arthroplasty. Impingement of the humeral plastic insert against the scapular neck is believed to be the cause of notching. There have been no in vivo studies that analyzed the positional relationship between the scapular neck and humeral insert. The purpose of this study was to measure the distance between the scapular neck and insert in shoulders with Grammont-type prostheses during active external rotation at the side.

Methods: Eighteen shoulders with Grammont-type prostheses were enrolled in this study. There were 13 males and 5 females, and the mean age at surgery was 74 years (range, 63-91). Fluoroscopic images were recorded during active external rotation at the side from maximum internal to external rotation at an average of 14 months (range, 7-24) after surgery. Implant kinematics were determined with three-dimensional models of the implants and fluoroscopic images using model-image registration techniques. Based on the implant kinematics, the closest distance between the scapular neck and insert was computed at each 5° increment of glenohumeral internal/external rotation.

Results: Mean glenohumeral abduction during rotation was 17°-22°. The mean distance between the neck and insert was approximately 1 mm throughout the activity. The separation distance tended to narrow with arm external rotation, but the change was not significant.

Interpretation: The small distance between the scapular neck and insert in early post-operative reverse shoulder arthroplasty patients may be associated with the high incidence of scapular notching in Grammont-type prostheses.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2021.105341DOI Listing

Publication Analysis

Top Keywords

scapular neck
24
external rotation
20
distance scapular
16
neck insert
16
active external
12
grammont-type prostheses
12
scapular
8
scapular notching
8
reverse shoulder
8
shoulder arthroplasty
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!