Recent reports have compared the analytical sensitivities of some SARS-CoV-2 RT-PCR assays, but differences in the viral materials used for these evaluations made comprehensive conclusions difficult. We carried out a direct comparison of the analytical sensitivities of 14 conventional and three rapid RT-PCR assays for the detection of SARS-CoV-2. The comparison was performed utilizing a certified reference material for SARS-CoV-2 RNA that was serially two-fold diluted in RNA storage solution. Our results show that the analytical sensitivities of the 17 assays varied within an 8-fold range (100-800 copies/mL). Moreover, a trend with some rapid assays yielding slightly higher analytical sensitivities (2- to 4-fold) compared with conventional assays was observed. We conclude that most of the RT-PCR assays can be used for routine COVID-19 diagnosis, but some assays with the poorest analytical sensitivities may lead to false-negative results when used to identify asymptomatic individuals who can carry a low viral load but still be infectious. These findings should be kept in mind when selecting high-sensitivity and rapid assays.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8008779PMC
http://dx.doi.org/10.1016/j.jviromet.2021.114144DOI Listing

Publication Analysis

Top Keywords

analytical sensitivities
20
rt-pcr assays
16
assays
9
conventional three
8
three rapid
8
rapid rt-pcr
8
rapid assays
8
analytical
6
sensitivities
5
analytical sensitivity
4

Similar Publications

Background: Per- and polyfluoroalkyl substances (PFAS) comprise thousands of fluorinated chemicals. They are of growing concern because many PFAS compounds are persistent and toxic. Food contact materials (FCM) containing PFAS pose multiple exposure pathways to humans, prompting twelve states to enact laws banning FCM with PFAS levels exceeding 100 ppm of TOF.

View Article and Find Full Text PDF

Adenosine receptors (A, A, A, A) play critical roles in cellular signaling and are implicated in various physiological and pathological processes, including inflammations and cancer. The main aim of this research was to investigate structure-activity relationships (SAR) to derive models that describe the selectivity and activity of inhibitors targeting Adenosine receptors. Structural information for 16,312 inhibitors was collected from BindingDB and analyzed using machine learning methods.

View Article and Find Full Text PDF

Introduction: Breath Volatile organic compounds (VOCs) are promising biomarkers for clinical purposes due to their unique properties. Translation of VOC biomarkers into the clinic depends on identification and validation: a challenge requiring collaboration, well-established protocols, and cross-comparison of data. Previously, we developed a breath collection and analysis method, resulting in 148 breath-borne VOCs identified.

View Article and Find Full Text PDF

A novel fluorescence sensing nanoplatform (CDs/AuNCs@ZIF-8) encapsulating carbon dots (CDs) and gold nanoclusters (AuNCs) within a zeolitic imidazolate framework-8 (ZIF-8) was developed for ratiometric detection of formaldehyde (FA) in the medium of hydroxylamine hydrochloride (NHOH·HCl). The nanoplatform exhibited pink fluorescence due to the aggregation-induced emission (AIE) effect of AuNCs and the internal filtration effect (IFE) between AuNCs and CDs. Upon reaction between NHOH·HCl and FA, a Schiff base formed via aldehyde-diamine condensation, releasing hydrochloric acid.

View Article and Find Full Text PDF

Aptamer-based fluorescence biosensor for rapid detection of chloramphenicol based on pyrene excimer switch.

Anal Bioanal Chem

January 2025

State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.

Chloramphenicol (CAP) is widely used in treating bacteria infection in animals and humans. However, the accumulation of CAP in food and environment caused serious health risk to human. Consequently, sensitive and selective detection of CAP is of great importance in environmental monitoring and food safety.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!