Improvement of Opal Multiplex Immunofluorescence Workflow for Human Tissue Sections.

J Histochem Cytochem

Department of Dermatology, Amsterdam University Medical Centers, location AMC, University of Amsterdam, Amsterdam, The Netherlands.

Published: May 2021

The Opal multiplex technique is an established methodology for the detection of multiple biomarkers in one section. The protocol encompasses iterative single stainings and heating-mediated removal of the primary and secondary antibodies after each staining round, leaving untouched the Opal fluorophores which are deposited onto the antigen of interest. According to our experience, repetitive heating of skin sections often results in tissue damage, indicating an urgent need for milder alternatives to strip immunoglobulins. In this study, we demonstrate that considerable heating-related damage was found not only in skin but also in tissues of different origin, mostly characterized by low cell density. Importantly, the morphology remained fully intact when sections were repetitively exposed to β-mercaptoethanol-containing stripping buffer instead of multiple heating cycles. However, target epitopes appeared sensitive at a differential degree to multiple treatments with stripping buffer, as shown by loss in staining intensity, but in all cases, the staining intensity could be restored by increment of the primary antibody concentrations. Application of β-mercaptoethanol-containing stripping buffer instead of heating for antibody removal markedly improved the quality of the Opal multiplex technique, as a substantial higher number of differently colored cells could be visualized within a well-conserved morphological context.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8091416PMC
http://dx.doi.org/10.1369/00221554211007793DOI Listing

Publication Analysis

Top Keywords

opal multiplex
12
stripping buffer
12
multiplex technique
8
β-mercaptoethanol-containing stripping
8
staining intensity
8
improvement opal
4
multiplex immunofluorescence
4
immunofluorescence workflow
4
workflow human
4
human tissue
4

Similar Publications

In this study, we present an ultrasensitive and specific multiplexed detection method for SARS-CoV-2 and influenza (Flu) utilizing CRISPR/Cas13a technology combined with a hydrogel-encapsulated photonic crystal (PhC) barcode integrated with hybridization chain reaction (HCR). The barcodes, characterized by core-shell structures, are fabricated through partial replication of periodically ordered hexagonally close-packed silicon dioxide beads. Consequently, the opal hydrogel shell of these barcodes features abundant interconnected pores that provide a substantial surface area for probe immobilization.

View Article and Find Full Text PDF

Lung dECM matrikine-based hydrogel reverses bleomycin-induced pulmonary fibrosis by suppressing M2 macrophage polarization.

Biofabrication

December 2024

Department of Respiratory and Critical Care Medicine, State Key Laboratory of Respiratory Health and Multimorbidity, Institute of Respiratory Health, Frontiers Science Center for Disease-related Molecular Network, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, People's Republic of China.

Recent studies have shown promising results using decellularized extracellular matrix (dECM) matrikines-based hydrogel as attractive strategies for preventing and alleviating fibrosis.Porcine lung decellularization and pepsin digestion were used to prepare the lung dECM hydrogel. Proteomic analysis revealed that the lung dECM hydrogel was enriched in glycoproteins, collagens, laminins, fibrinogen, held receptors, and bound growth factors.

View Article and Find Full Text PDF

Expression features of targets for anti-glioma CAR-T cell immunotherapy.

J Neurooncol

January 2025

Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Nan Si Huan Xi Lu 119, Beijing, 100070, China.

Objective: To investigate the expression features of common anti-glioma CAR-T targets (B7H3, CSPG4, EGFRv III, HER2 and IL-13Ra2) in gliomas with different grades and molecular subtypes, and explore the association of target expression with glioma malignant or immune phenotypes including immune evasion, stemness, antigen presentation, and tumor angiogenesis.

Methods: Opal™ Multiplex immunofluorescence staining was performed on glioma tissues to detect the expression of targets, and biomarkers related to the phenotypes.

Results: High variety of CAR-T target expression among glioma subtypes was observed.

View Article and Find Full Text PDF

Protocol to characterize mouse intestinal epithelial cell lineage using Opal multiplex immunofluorescence.

STAR Protoc

September 2024

Department of Pathology and Laboratory Medicine, Weill Cornell Medicine, New York, NY 10065, USA. Electronic address:

Applying Opal multiplex immunofluorescence (OMI) to characterize intestinal tissues of genetically engineered mouse models provides an excellent tool for studying complex processes. However, detecting appropriate signals from multiple target molecules is challenging. Here, we present a protocol to characterize mouse intestinal epithelial cell lineage using OMI.

View Article and Find Full Text PDF

Integrated biosensor array for multiplex biomarkers cancer diagnosis via in-situ self-assembly carbon nanotubes with an ordered inverse-opal structure.

Biosens Bioelectron

October 2024

Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics, South China Normal University, Guangzhou, 510006, PR China; Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou, 510006, PR China. Electronic address:

To enhance the precision and reliability of early disease detection, especially in malignancies, an exhaustive investigation of multi-target biomarkers is essential. In this study, an advanced integrated electrochemical biosensor array that demonstrates exceptional performance was constructed. This biosensor was developed through a controllable porous-size mechanism and in-situ modification of carbon nanotubes (CNTs) to quantify multiplex biomarkers-specifically, C-reaction protein (CRP), carbohydrate antigen 125 (CA125), and carcinoembryonic antigen (CEA)-in human serum plasma.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!