Objective: Studies confirm the benefit of surgical treatment for fixation of displaced midshaft clavicle fractures. Plate fixation and intramedullary nail are the two most used techniques. Our study seeks to compare these two surgical techniques.
Methods: This is a retrospective study, conducted by the evaluation of patients treated for displaced midshaft clavicle fracture with intramedullary nail, and plate and screws. Socioeconomic variables were collected, a visual pain scale questionnaire was applied, the shoulder function was measured using CONSTANT and UCLA scores, and radiography was performed to verify the consolidation and evaluation of the final clavicle shortening.
Results: Sixty-five patients were evaluated, 36 (55.4%) of which were subjected to clavicle fixation with plate and screws and 29 (44.6%) with intramedullary nail. The median shortening was 0.1mm for plate and 5.8mm for nail (p = 0.001). The UCLA score shows an average of 35 in the plate group and 35 in the intramedullary group. The median CONSTANT scores were 96.5 for plate and 95 for nail, without significance. In all groups, 13 (20%) complications were registered, 9 fixed with plate and 4 fixed with intramedullary nail. The most common complication was skin erosion with exposure of the synthetic material. The two techniques present satisfactory results for the treatment of displaced midshaft clavicle fractures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7976870 | PMC |
http://dx.doi.org/10.1590/1413-785220212901231439 | DOI Listing |
Mymensingh Med J
January 2025
Dr Md Sonaullah, Assistant Professor, Department of Orthopedics and Traumatology, Mymensingh Medical College (MMC), Mymensingh, Bangladesh; E-mail:
Subtrochanteric femoral fractures are one of the common fractures encountered in today's Orthopaedic practice. This area consists of mostly cortical bone with high stress generation thus heal slowly which leads implant failure. The inherent instability of this fracture and forces of the muscles with comminuted medial calcar is giving the fracture a tendency to varus collapse.
View Article and Find Full Text PDFEur J Orthop Surg Traumatol
December 2024
Department of Orthopedics and Trauma, Universidade Federal Fluminense (UFF), Niterói, Rio de Janeiro, Brazil.
Purpose: Although several techniques have been described for bent intramedullary nail removal, there is no universally accepted strategy. We hypothesized that a device based on the action principle of a three-point bend fixture could facilitate extraction of bent intramedullary nails; this paper describes its design and experimental testing.
Methods: Five large synthetic left femurs and five steel intramedullary nails were used.
Cureus
November 2024
Trauma and Orthopaedics, Hull Royal Infirmary, Hull, GBR.
Introduction Paediatric forearm fractures are common, but isolated radial diaphyseal fractures are rare, representing a small subset. Unlike fractures involving both the radius and ulna, these fractures lack well-established management guidelines. The potential for alignment loss during treatment underscores the need for specific protocols.
View Article and Find Full Text PDFInjury
December 2024
Department of Orthopaedics, Larnaca General Hospital, State Health Services Organisation, Larnaca, Cyprus.
The purpose of this study was to establish typical dose values at orthopaedic operating rooms of the Larnaca General Hospital (LGH). Kerma area product (KAP), fluoroscopy time (FT) and cumulative air-kerma (K) measurements were collected for 821 patients who underwent common and reproducible trauma surgery over a five-year period, with three mobile C-arm systems; two equipped with an image-intensifier and one with a flat-panel detector. Dose indices were automatically extracted from radiation dose structured reports or DICOM meta-data files archived in the PACS, using custom-made software.
View Article and Find Full Text PDFJt Dis Relat Surg
January 2025
Dr. Abdurrahman Yurtaslan Ankara Onkoloji Eğitim ve Araştırma Hastanesi, Ortopedi ve Travmatoloji Kliniği, 06200 Yenimahalle, Ankara, Türkiye.
Objectives: This study aimed to investigate the importance of the Dorr index in the preoperative evaluation of implant failure in patients who underwent proximal femoral nail (PFN).
Patients And Methods: This retrospective study examined 312 patients who underwent PFN for intertrochanteric fractures between January 2016 and January 2020. Patients with unstable fractures according to the AO/OTA (AO Foundation/Orthopaedic Trauma Association) classification, those over 65 years of age, with at least one year of regular follow-up, a tip-apex distance <25 mm, and a caput-collum-diaphyseal angle between 125° and 135°, were included.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!