A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

First-in-Man trial of a drug-free bioresorbable stent designed to minimize the duration of coronary artery scaffolding. | LitMetric

For the last two decades, various degradable stents have been proposed to treat coronary artery diseases and replace metallic stents to avoid residual foreign material after healing. To date, the right balance between suitable scaffolding and loss of radial strength soon after endothelium restoration is still an unmet need. The present article reports on the First-in-Man trial of a drug-free bioresorbable stent based on a lactic acid stereocopolymer composed of 98% l-lactyl units selected to release stress shielding earlier than in the case of homopoly(l-lactic acid). Thirty patients with single coronary lesions were included in the trial. The fate of scaffolds was monitored by clinical and imaging follow-ups to assess rate of adverse events, acute recoil, late luminal loss, and late lumen recovery. There was no death, no myocardial infarction, and no stent thrombosis observed over the 36 months trial. Dismantling occurred about 3 months after implantation. Bioresorption was almost completed at 2 years. The late lumen loss observed at the end of the first year was partly compensated one year later by enlarging remodeling. At one year, a neointimal hyperplasia slightly greater than for drug-eluting metallic and bioresorbable stents was shown using optical coherence tomography. The excess of hyperplasia was discussed relative to struts thickness, absence of anti-proliferative drug, and release of degradation by-products.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09205063.2021.1910919DOI Listing

Publication Analysis

Top Keywords

first-in-man trial
8
trial drug-free
8
drug-free bioresorbable
8
bioresorbable stent
8
coronary artery
8
late lumen
8
stent designed
4
designed minimize
4
minimize duration
4
duration coronary
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!