A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Convoluted Tubules of the Nephron Must Be Considered Elliptical, and Not Circular, in Stereological Studies of the Kidney. | LitMetric

Introduction: The diameter and area of the proximal convoluted tubule (PCT) and the distal convoluted tubule (DCT) are of the main parameters analyzed in stereological studies of the kidney. However, there is no consensus about if the PCT and DCT should be considered circular or elliptical in shape.

Objective: To analyze if there are significant differences in the diameter and area of the PCT and DCT, depending on whether they are considered circular or elliptical.

Methods: Paraffin-embedded sections of kidneys from CD1 mice were stained with hematoxylin and eosin and examined using a light microscope. Images were captured using a camera linked to image analysis software. A short diameter (d) and a long diameter (D) were measured in both PCT and DCT. A small circular area (SCA), a large circular area (LCA), and an elliptical area (EA) were calculated with mathematical formulas that incorporate d and D values, while a program area (PA) was provided by the software.

Results: There was a significant difference between d and D in both PCT (F = 1.354, Sig = 0.000) and DCT (F = 4.989, Sig = 0.000). Also, there were significant differences in the tubular areas in both PCT (F = 34.843, Sig = 0.000) and DCT (F = 22.390, Sig = 0.000); circular areas were different from elliptical areas (SCA and LCA vs. EA and PA).

Conclusion: The convoluted tubules of the nephron must not be considered circular, but rather elliptical; care should be taken every time the tubules are analyzed in stereological studies of the kidney, especially when evaluating their diameters and areas.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000515051DOI Listing

Publication Analysis

Top Keywords

sig 0000
16
stereological studies
12
studies kidney
12
pct dct
12
considered circular
12
convoluted tubules
8
tubules nephron
8
nephron considered
8
diameter area
8
convoluted tubule
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!