Background: Medication errors are a common problem in hospitals and a major driver of adverse patient outcomes. Barcode verification technology is a promising strategy to help ensure safe medication preparation practices.

Objectives: The objectives of this study were (i) to assess the effects of a barcode-assisted medication preparation and administration system regarding the rate of medication preparation errors and (ii) to compare the time spent on medication preparation tasks by medical staff.

Methods: A quasi-experimental study with a pre-post design was conducted, from August 2017 to July 2018, in two mixed medical/surgical units of a tertiary teaching hospital. The primary aim was to assess the effects of a barcode-based electronically assisted medication preparation and administration system linked to the hospital's electronic medication administration record regarding the rate of medication preparation errors and time-based staff performance. Data were collected using direct observation. Adjusted and unadjusted logistic models were used for error frequencies and linear regression models for time performance.

Results: 5932 instances of medication selection and dosing during 79 medication preparation procedures were observed. The overall medication preparation error incidence decreased from 9.9% at baseline to 4.5% at post-intervention, corresponding to a relative risk reduction of 54.5% (P < 0.001). However, the adjusted effect by registered nurses (RNs) and nurses' work experience of total medication preparation errors showed only borderline significance (odds ratio [OR] 0.64, P = 0.051). For adjusted error-specific analyses, significant error reductions were found in wrong medication errors (OR 0.38, P < 0.010) and wrong dosage errors (OR 0.12, P = 0.004). Wrong patient, wrong form and ambiguous dispenser errors did not occur at post-intervention. Errors of omission (OR 1.53, P = 0.17), additional doses (OR 0.63, P = 0.64) and wrong dispenser boxes (OR 0.51, P = 0.11) did not change significantly. The time necessary to prepare medications for a 24-h period also decreased significantly-from 30.2 min to 17.2 min (beta = -6.5, P = 0.047), while mean preparation time per individual medication dose fell from 24.3 s to 15.1 s (beta = -5.0, P = 0.002).

Conclusion: Use of the new barcode technology significantly reduced the rate of some medication preparation errors in our sample. Moreover, the time necessary for medication preparation, both per 24-h period and per single-medication dose, was significantly reduced.

Download full-text PDF

Source
http://dx.doi.org/10.1093/intqhc/mzab043DOI Listing

Publication Analysis

Top Keywords

medication preparation
36
medication
12
preparation
9
quasi-experimental study
8
assess effects
8
preparation administration
8
administration system
8
rate medication
8
preparation errors
8
barcode technology
4

Similar Publications

Azo dye was used to prepare a new series of complexes with chlorides of rhodium (Rh), ruthenium (Ru), and corona (Au). The prepared materials were subjected to infrared, ultraviolet-visible, and mass spectrometry, as well as thermogravimetric analysis, differential calorimetry, and elemental analysis. Conductivity, magnetic susceptibility, metal content, and chlorine content of the complexes were also measured.

View Article and Find Full Text PDF

Percutaneous coronary interventions in highly calcified atherosclerotic lesions are challenging due to the high mechanical stiffness that significantly restricts stent expansion. Intravascular lithotripsy (IVL) is a novel vessel preparation technique with the potential to improve interventional outcomes by inducing microscopic and macroscopic cracks to enhance stent expansion. However, the exact mechanism of action for IVL is poorly understood, and it remains unclear whether the improvement in-stent expansion is caused by either the macro-cracks allowing the vessel to open or the micro-cracks altering the bulk material properties.

View Article and Find Full Text PDF

Chemotherapy resistance (CR) represents one of the most important barriers to effective oncological therapy and often leads to ineffective intervention and unfavorable clinical prognosis. Emerging studies have emphasized the vital significance of extracellular RNA (exRNA) in influencing CR. This thorough assessment intends to explore the multifaceted contributions of exRNA, such as exosomal RNA, microRNAs, long non-coding RNAs, and circular RNAs, to CR in cancer.

View Article and Find Full Text PDF

Left ventricular rigor mortis interferes with postmortem aortic root geometry.

Int J Legal Med

January 2025

Institute for Legal Medicine, Faculty of Medicine, Saarland University, Campus Homburg, Building 49.1, Kirrberger Straße 100, 66421, Homburg/Saar, Germany.

Aortic regurgitation is a common valve disease and can be caused by delineated findings such as fenestrations or hardly discernible alterations of the aortic root geometry. Therefore, aortic regurgitation can be a challenging diagnosis during an autopsy. Cardiac surgeons, however, are confronted with comparable problems during surgery and have developed a refined knowledge of the anatomy of the aortic root including its geometry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!