Infrared thermometry has been proposed as an interesting alternative to probe thermometers for recording ear temperature in cadavers to estimate the postmortem interval (PMI), but it has still to be validated in this setting. Our objective was to compare the performance of an infrared thermometer to that of a reference probe thermometer for measuring ear temperature. Temperature measurements were performed on 100 cadavers (mean PMI: 4.5 ± 2.5 h) using the infrared and the probe thermometers. The repeatability of the measurements, their correlation, and the agreement between both methods were evaluated. We showed a good repeatability of the measurements with the infrared thermometer (Lin's concordance correlation coefficient (CCC) = 0.93 [0.72;0.98] for the right ear; CCC = 0.94 [0.75;0.98] for the left ear), and there was a strong and significant correlation between measurements provided by the two instruments (p < 0.001). However, a poor agreement was found between both methods, with a systematic underestimation of about 2 °C of the ear temperature when measured with the infrared thermometer. Data from auricular infrared thermometry should not be applied to algorithms developed for probe thermometers to estimate the PMI. Further research is needed to develop a reliable algorithm specifically based on infrared thermometry.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00414-021-02579-yDOI Listing

Publication Analysis

Top Keywords

infrared thermometry
8
probe thermometers
8
ear temperature
8
infrared thermometer
8
repeatability measurements
8
infrared
5
ear
5
thermometry suitable
4
suitable determination
4
determination time
4

Similar Publications

Luminescent materials doped with rare-earth (RE) ions have emerged as powerful tools in thermometry, offering high sensitivity and accuracy. However, challenges remain, particularly in maintaining efficient luminescence at elevated temperatures. This study investigates the thermometric properties of BiVO: Yb/Er (BVO: Er/Yb) nanophosphors synthesized the sol-gel method.

View Article and Find Full Text PDF

The aim of this study was to analyze the association between circulating amino acids and central and peripheral body temperature in subjects with and without fibromyalgia syndrome (FMS). A total of 47 patients with FMS and 59 healthy subjects were included in the study. The concentration of amino acids was determined in serum samples using a fluorimeter coupled with a high-performance liquid chromatography system.

View Article and Find Full Text PDF

Background: Non-invasive temporal artery thermometers (TATs) and non-contact infrared thermometers (NCITs) are increasingly used in community settings to measure body temperature. Existing research predominantly focuses on pediatric populations, yet the accuracy and precision of TATs and NCITs for fever screening across age groups remain unclear. This study aims to assess age-related differences in the diagnostic accuracy of TATs and NCITs for fever detection.

View Article and Find Full Text PDF

Research on multifunctional luminous materials has garnered a lot of interest in the fields of optical sensing, biological imaging, white light-emitting diodes illumination, etc. A novel multifunctional phosphor of Pr-doped BiMoO (BMO: Pr), created via the solid-state method, was investigated in this work. X-ray diffraction, scanning electron microscopy, diffuse reflectance spectroscopy, photoluminescence spectra, and fluorescence decay curves were employed to analyze the produced phosphors.

View Article and Find Full Text PDF

Constructing a Self-Referenced NIR-II Thermometer with Energy Tuning of Coordinating Water Molecules by a Minimalist Method.

ACS Appl Mater Interfaces

January 2025

State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China.

Fluorescence thermometry based on metal halide perovskites is increasingly becoming a hotspot due to its advantages of high detection sensitivity, noninvasiveness, and fast response time. However, it still presents certain technical challenges in practical applications, such as complex synthesis methods, the use of toxic solvents, and being currently mainly based on the visible/first near-infrared light with poor penetration and severe autofluorescence. In this study, we synthesize the second near-infrared (NIR-II) luminescent crystals based on Yb/Nd-doped zero-dimensional CsScCl·HO by a simple "dissolve-dry" method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!