Vascularization and bone regeneration are two closely related processes during bone reconstruction. A three-dimensional (3D) scaffold with porous architecture provides a suitable microenvironment for vascular growth and bone formation. Here, we present a simple and general strategy to construct a nanofibrous poly(l-lactide)/poly(ε-caprolactone) (PLLA/PCL) scaffold with interconnected perfusable microchannel networks (IPMs) based on 3D printing technology by combining the phase separation and sacrificial template methods. The regular and customizable microchannel patterns within the scaffolds (spacings: 0.4 mm, 0.5 mm, and 0.6 mm; diameters: 0.8 mm, 1 mm, and 1.2 mm) were made to investigate the effect of microchannel structure on angiogenesis and osteogenesis. The results of subcutaneous embedding experiment showed that 0.5/0.8-IPMs (spacing/diameter = 0.5/0.8) and 0.5/1-IPMs (spacing/diameter = 0.5/1) scaffolds exhibited more vascular network formation as compared with other counterparts. After loading with vascular endothelial growth factor (VEGF), VEGF@IPMs-0.5/0.8 scaffold prompted better human umbilical vein endothelial cells (HUVECs) migration and neo-blood vessel formation, as determined by Transwell migration, scratch wound healing, and chorioallantoic membrane (CAM) assays. Furthermore, the microangiography and rat cranial bone defects experiments demonstrated that VEGF@IPMs-0.5/0.8 scaffold exhibited better performance in vascular network formation and new bone formation compared to VEGF@IPMs-0.5/1 scaffold. In summary, our results suggested that the microchannel structure within the scaffolds could be tailored by an adjustable caramel-based template strategy, and the combination of interconnected perfusion microchannel networks and angiogenic factors could significantly enhance vascularization and bone regeneration.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7970223 | PMC |
http://dx.doi.org/10.1016/j.bioactmat.2021.02.033 | DOI Listing |
Sci Rep
December 2024
Computer Engineering Department, Lorestan University, Khorramabad, Iran.
This paper presents a slot antenna integrated with a split ring resonator (SRR) and feed line, designed to achieve a high Q-factor while maximizing channel capacity utilization. By incorporating a lens into the dielectric resonator antenna (DRA), we enhance both bandwidth and directivity, with the dielectric material's permittivity serving as a key control parameter for radiation characteristics. We explore water and ethanol as controllable dielectrics within the terahertz (THz) frequency range (0.
View Article and Find Full Text PDFMicrosyst Nanoeng
December 2024
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100190, People's Republic of China.
Microfluidic impedance flow cytometry has been widely used in leukocyte differential and counting, but it faces a bottleneck due to the trade-off between impedance detection throughput and sensitivity. In this study, a microfluidic impedance flow cytometer based on a virtual constriction microchannel was reported, in which the virtual constriction microchannel was constructed by crossflow of conductive sample and insulated sheath fluids with underneath micro-electrodes for impedance measurements. Compared to conventional mechanical constriction microchannels, this virtual counterpart could effectively avoid direct physical contact between cells and the microchannel walls to maintain high throughputs, and significantly reduce the volume of the impedance detection region for sensitivity improvements.
View Article and Find Full Text PDFMicromachines (Basel)
November 2024
Department of Pure and Applied Physics, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo 169-8555, Japan.
Wiring technology to control the length and direction of neurite outgrowth and to connect them is one of the most crucial development issues for forming single-cell-based neuronal networks. However, with current neurite wiring technology, it has been difficult to stop neurite extension at a specific length and connect it to other neurites without causing miswiring due to over-extension. Here, we examined a novel method of wiring neurites without miswiring by controlling the length of neurites in open-ended bending microchannel arrays connected beyond the maximum bending angle of neurite outgrowth.
View Article and Find Full Text PDFSmall Methods
November 2024
Department of Mechanical Engineering, American University of Sharjah, Sharjah, UAE.
The purpose of this study is to characterize the dynamic response of fluid flow in microchannels, which can show significant delay times before reaching steady flow conditions. Two main sources of these delays are numerically and experimentally investigated, the hydraulic compliance which originates from the flexibility of the system components (microchannel, tubing, syringe, etc.), and the compressibility of the liquid dead volume in the setup, also known as the "bottleneck effect".
View Article and Find Full Text PDFSmall
November 2024
Delft University of Technology, Delft, 2628 CD, The Netherlands.
Synchronization plays a crucial role in the dynamics of living organisms. Uncovering the mechanism behind it requires an understanding of individual biological oscillators and the coupling forces between them. Here, a single-cell assay is developed that studies rhythmic behavior in the motility of E.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!