Brain-computer interface (BCI) training is becoming increasingly popular in neurorehabilitation. However, around one third subjects have difficulties in controlling BCI devices effectively, which limits the application of BCI training. Furthermore, the effectiveness of BCI training is not satisfactory in stroke rehabilitation. Intermittent theta burst stimulation (iTBS) is a powerful neural modulatory approach with strong facilitatory effects. Here, we investigated whether iTBS would improve BCI accuracy and boost the neuroplastic changes induced by BCI training. Eight right-handed healthy subjects (four males, age: 20-24) participated in this two-session study (BCI-only session and iTBS+BCI session in random order). Neuroplastic changes were measured by functional near-infrared spectroscopy (fNIRS) and single-pulse transcranial magnetic stimulation (TMS). In BCI-only session, fNIRS was measured at baseline and immediately after BCI training. In iTBS+BCI session, BCI training was followed by iTBS delivered on the right primary motor cortex (M1). Single-pulse TMS was measured at baseline and immediately after iTBS. fNIRS was measured at baseline, immediately after iTBS, and immediately after BCI training. Paired-sample -tests were used to compare amplitudes of motor-evoked potentials, cortical silent period duration, oxygenated hemoglobin (HbO2) concentration and functional connectivity across time points, and BCI accuracy between sessions. No significant difference in BCI accuracy was detected between sessions ( > 0.05). In BCI-only session, functional connectivity matrices between motor cortex and prefrontal cortex were significantly increased after BCI training ('s < 0.05). In iTBS+BCI session, amplitudes of motor-evoked potentials were significantly increased after iTBS ('s < 0.05), but no change in HbO2 concentration or functional connectivity was observed throughout the whole session ('s > 0.05). To our knowledge, this is the first study that investigated how iTBS targeted on M1 influences BCI accuracy and the acute neuroplastic changes after BCI training. Our results revealed that iTBS targeted on M1 did not influence BCI accuracy or facilitate the neuroplastic changes after BCI training. Therefore, M1 might not be an effective stimulation target of iTBS for the purpose of improving BCI accuracy or facilitate its effectiveness; other brain regions (i.e., prefrontal cortex) are needed to be further investigated as potentially effective stimulation targets.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7994768 | PMC |
http://dx.doi.org/10.3389/fncel.2021.653487 | DOI Listing |
Alzheimers Dement
December 2024
German Center for Neurodegenerative Diseases (DZNE), Magdeburg, Germany.
Background: Training studies report beneficial effects of physical (PP) on cognitive performance (COG) in older adults, but are often accompanied by potentially biased parameters, conclusions, and lack of directionality. To address these issues, we used a dynamic Bayesian approach to analyse the dynamic session-to-session change and coupling of PP and COG over time.
Methods: We used two studies (N = 17 each): Study 1 contained 24-weeks (72 sessions) of training of older adults with suspected Alzheimer's disease (AD).
Alzheimers Dement
December 2024
German Center for Neurodegenerative Diseases (DZNE), Magdeburg, Germany.
Background: Training studies report beneficial effects of physical (PP) on cognitive performance (COG) in older adults, but are often accompanied by potentially biased parameters, conclusions, and lack of directionality. To address these issues, we used a dynamic Bayesian approach to analyse the dynamic session-to-session change and coupling of PP and COG over time.
Methods: We used two studies (N = 17 each): Study 1 contained 24-weeks (72 sessions) of training of older adults with suspected Alzheimer's disease (AD).
Front Hum Neurosci
December 2024
Donders Institute for Brain, Cognition and Behaviour, Radboud University, Nijmegen, Netherlands.
Introduction: As brain-computer interfacing (BCI) systems transition fromassistive technology to more diverse applications, their speed, reliability, and user experience become increasingly important. Dynamic stopping methods enhance BCI system speed by deciding at any moment whether to output a result or wait for more information. Such approach leverages trial variance, allowing good trials to be detected earlier, thereby speeding up the process without significantly compromising accuracy.
View Article and Find Full Text PDFSensors (Basel)
December 2024
College of Computer and Information Sciences (CCIS), King Saud University, Riyadh 11543, Saudi Arabia.
One of the most promising applications for electroencephalogram (EEG)-based brain-computer interfaces (BCIs) is motor rehabilitation through motor imagery (MI) tasks. However, current MI training requires physical attendance, while remote MI training can be applied anywhere, facilitating flexible rehabilitation. Providing remote MI training raises challenges to ensuring an accurate recognition of MI tasks by healthcare providers, in addition to managing computation and communication costs.
View Article and Find Full Text PDFSensors (Basel)
December 2024
College of Design and Innovation, Tongji University, Shanghai 200092, China.
Artificial intelligence (AI) systems are widely applied in various industries and everyday life, particularly in fields such as virtual assistants, healthcare, and education. However, this paper highlights that existing research has often overlooked the philosophical and media aspects. To address this, we developed an interactive system called "Human Nature Test".
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!