In vitro analysis of the interaction of tear film inflammatory markers with contemporary contact lens materials.

Cont Lens Anterior Eye

Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada; Centre for Eye & Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong.

Published: October 2021

Purpose: Several clinical studies have suggested that reusable silicone hydrogel contact lens materials exhibit a two-times increased rate of corneal infiltrative events compared to reusable hydrogels. One potential factor contributing to this complication relates to the differential uptake of tear film-based pro-inflammatory cytokines. The purpose of this study was to use an in vitro assay to investigate whether four pro-inflammatory cytokines differed in their uptake onto six contemporary contact lens materials.

Methods: Conventional hydrogel (etafilcon A, omafilcon A) and silicone hydrogel (balafilcon A, comfilcon A, senofilcon A, somofilcon A) contact lens materials were soaked in solutions containing pro-inflammatory cytokines IL-1β, IL-6, IL-8 and TNF-α. Samples of the soaking solutions were collected over various time points and analyzed using the Meso Scale Discovery system, which served as a measurement of cytokine uptake onto the contact lens materials.

Results: Both conventional hydrogels (etafilcon A, omafilcon A) and two of the four silicone hydrogels tested (balafilcon A, comfilcon A), exhibited some uptake of IL-1β, IL-8 or TNF-α (p < 0.05). Senofilcon A and somofilcon A did not exhibit uptake of any of these cytokines (p > 0.05). There was no uptake of IL-6 onto any of the contact lens materials investigated (p > 0.05).

Conclusion: The contact lens materials tested did not exhibit any uptake of IL-6 and furthermore, did not exhibit more than 10 ± 3 % to 25 ± 12 % uptake of IL-1β, IL-8 or TNF-α. Numerous factors could contribute to the reported increase in corneal infiltrative events with reusable silicone hydrogel materials, however, based on these results, it appears that uptake of these four cytokines are unlikely to contribute to this finding.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2021.02.016DOI Listing

Publication Analysis

Top Keywords

contact lens
28
lens materials
20
silicone hydrogel
12
pro-inflammatory cytokines
12
il-8 tnf-α
12
exhibit uptake
12
uptake
9
contemporary contact
8
reusable silicone
8
corneal infiltrative
8

Similar Publications

Bioinspired Heterogeneous Surface for Radiative Cooling Enhanced Power-Free Moisture Harvesting in Unsaturated Atmosphere.

Adv Mater

December 2024

Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure and Hubei Engineering Research Center for Biomaterials and Medical Protective Materials, Huazhong University of Science and Technology, Wuhan, 430074, P. R. China.

The development of zero-power moisture-harvesting technology in an unsaturated atmosphere is of great significance for coping with global freshwater scarcity. Here, inspired by Pachydactylus rangei's (Namib sand gecko) ability to evade thermal radiation and harvest moisture, a power-free cooling moisture harvester (PFCMH) is fabricated using the continuous, industrialized micro-extrusion compression molding. A Luneburg lens is introduced in the PFCMH for the first time, endowing it with a high reflectivity of ≈92.

View Article and Find Full Text PDF

Structural Color Contact Lenses from Cholesteric Cellulose Liquid Crystals.

Small Methods

December 2024

Institute of Translational Medicine, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.

Colored contact lenses have gained popularity among young individuals owing to their ability to alter the appearance of the wearer's eyes. However, conventional lenses containing chemical dyes are susceptible to detachment of the pigment layer, which can lead to corneal damage. In this research, a novel cellulose-based structural color contact lens (SCCL) is presented that enhances aesthetic appeal via a cholesteric liquid crystal (CLC) layer.

View Article and Find Full Text PDF

Background: Contact lens discomfort (CLD) is a common problem for CL wearers, and patients with CLD often have changes in meibomian gland function and structure. In a Phase 2 trial AZR-MD-001 0.5% (AZR) ophthalmic ointment improved meibomian gland dysfunction (MGD) in non-lens wearers.

View Article and Find Full Text PDF

Background Computer vision syndrome (CVS) is a common condition affecting individuals who spend prolonged periods using electronic devices. It is characterized by symptoms such as eye strain, dryness, headaches, and neck pain. This study aims to assess the prevalence of CVS symptoms among healthcare professionals, their awareness of the condition, and the effectiveness of various preventative practices.

View Article and Find Full Text PDF

Acquired Ankyloblepharon Correction Using Ocular Surface and Tarsal Mucous Membrane Grafting in Cicatrizing Ocular Surface Diseases.

Ophthalmic Plast Reconstr Surg

October 2024

Hariram Motumal Nasta & Renu Hariram Nasta Ophthalmic Plastic Surgery Services.

Purpose: To report the long-term surgical outcomes of acquired ankyloblepharon correction using mucous membrane graft.

Methods: Five eyes of 4 patients (median age, 19 years) with acquired ankyloblepharon were managed using eyelid splitting and mucous membrane graft anchored to the recti muscles on the bulbar surface in the respective quadrant and onto the bare tarsal surface. Outcome measures include a change in the palpebral fissure width, ability to fit scleral contact lenses, visual acuity, and cosmesis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!