The paper presents a 256-pixel CMOS sensor array with in-pixel dual electrochemical and impedance detection modalities for rapid, multi-dimensional characterization of exoelectrogens. The CMOS IC has 16 parallel readout channels, allowing it to perform multiple measurements with a high throughput and enable the chip to handle different samples simultaneously. The chip contains a total of 2 × 256 working electrodes of size 44 μm × 52 μm, along with 16 reference electrodes of dimensions 56 μm × 399 μm and 32 counter electrodes of dimensions 399 μm × 106 μm, which together facilitate the high resolution screening of the test samples. The chip was fabricated in a standard 130nm BiCMOS process. The on-chip electrodes are subjected to additional fabrication processes, including a critical Al-etch step that ensures the excellent biocompatibility and long-term reliability of the CMOS sensor array in bio-environment. The electrochemical sensing modality is verified by detecting the electroactive analyte NaFeEDTA and the exoelectrogenic Shewanella oneidensis MR-1 bacteria, illustrating the chip's ability to quantify the generated electrochemical current and distinguish between different analyte concentrations. The impedance measurements with the HEK-293 cancer cells cultured on-chip successfully capture the cell-to-surface adhesion information between the electrodes and the cancer cells. The reported CMOS sensor array outperforms the conventional discrete setups for exoelectrogen characterization in terms of spatial resolution and speed, which demonstrates the chip's potential to radically accelerate synthetic biology engineering.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TBCAS.2021.3068710 | DOI Listing |
We present a widefield fluorescence microscope that integrates an event-based image sensor (EBIS) with a CMOS image sensor (CIS) for ultra-fast microscopy with spectral distinction capabilities. The EBIS achieves a temporal resolution of ∼10s (∼ 100,000 frames/s), while the CIS provides diffraction-limited spatial resolution. A diffractive optical element encodes spectral information into a diffractogram, which is recorded by the CIS.
View Article and Find Full Text PDFUtilizing the periodic pixel configuration of the CCD/CMOS imaging sensor as the reference grating and the image of the real grating formed by the lens as the specimen grating, the CCD Moiré method directly outputs amplified Moiré fringes, facilitating high-resolution, full-field deformation measurement. Due to the amplification effect of CCD Moiré, even minor relative rotations of the two gratings can significantly affect Moiré imaging and introduce measurable errors. This paper mainly addresses the imaging and measurement challenges of in-plane rotation in the CCD Moiré method.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Institute of Electronics, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan.
Single-Photon Avalanche Photodiodes (SPADs) are increasingly utilized in high-temperature-operated, high-performance Light Detection and Ranging (LiDAR) systems as well as in ultra-low-temperature-operated quantum science applications due to their high photon sensitivity and timing resolution. Consequently, the jitter value of SPADs at different temperatures plays a crucial role in LiDAR systems and Quantum Key Distribution (QKD) applications. However, limited studies have been conducted on this topic.
View Article and Find Full Text PDFWater Res
January 2025
Department of Mechanical Engineering, Sogang University, Seoul, South Korea; Institute of Integrated Biotechnology, Sogang University, Seoul, South Korea; Department of Biomedical Engineering, Sogang University, Seoul, South Korea; Institute of Smart Biosensor, Sogang University, Seoul, South Korea. Electronic address:
Microplastic (MP) pollution poses serious environmental and public health concerns, requiring efficient detection methods. Conventional techniques have the limitations of labor-intensive workflows and complex instrumentation, hindering rapid on-site field analysis. Here, we present the Machine learning (ML)-Integrated Droplet-based REal-time Analysis of MP (MiDREAM) system.
View Article and Find Full Text PDFMicrosyst Nanoeng
January 2025
State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, 518060, Shenzhen, China.
We present a system-level model with an on-chip temperature compensation technique for a CMOS-MEMS monolithic calorimetric flow sensing SoC. The model encompasses mechanical, thermal, and electrical domains to facilitate the co-design of a MEMS sensor and CMOS interface circuits on the EDA platform. The compensation strategy is implemented on-chip with a variable temperature difference heating circuit.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!