AI Article Synopsis

  • Aerosol transmission is now recognized as the main way COVID-19 spreads, emphasizing the critical role of ventilation to reduce risks.
  • Most existing mechanical ventilation systems prioritize comfort rather than controlling airborne infections, falling short of the recommended air changes needed for safety.
  • Effective solutions like portable air cleaners and upper room germicidal UV (GUV) disinfection are highlighted, with GUV being particularly effective at significantly reducing SARS-CoV-2 spread.

Article Abstract

Aerosol transmission is now widely accepted as the principal way that COVID-19 is spread, as has the importance of ventilation-natural and mechanical. But in other than healthcare facilities, mechanical ventilation is designed for comfort, not airborne infection control, and cannot achieve the 6 to 12 room air changes per hour recommended for airborne infection control. More efficient air filters have been recommended in ventilation ducts despite a lack of convincing evidence that SARS-CoV-2 virus spreads through ventilation systems. Most transmission appears to occur in rooms where both an infectious source COVID-19 case and other susceptible occupants share the same air. Only two established room-based technologies are available to supplement mechanical ventilation: portable room air cleaners and upper room germicidal UV air disinfection. Portable room air cleaners can be effective, but performance is limited by their clean air delivery rate relative to room volume. SARS-CoV-2 is highly susceptible to GUV, an 80-year-old technology that has been shown to safely, quietly, effectively and economically produce the equivalent of 10 to 20 or more air changes per hour under real life conditions. For these reasons, upper room GUV is the essential engineering intervention for reducing COVID-19 spread.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8251047PMC
http://dx.doi.org/10.1111/php.13421DOI Listing

Publication Analysis

Top Keywords

airborne infection
12
infection control
12
room air
12
air
9
air disinfection
8
covid-19 spread
8
mechanical ventilation
8
air changes
8
changes hour
8
portable room
8

Similar Publications

Pollution profiles, pathogenicity, and toxicity of bioaerosols in the atmospheric environment of urban general hospital in China.

Environ Pollut

January 2025

Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China.

Airborne microorganisms in hospitals present significant health risks to both patients and employees. However, their pollution profiles and associated hazards in different hospital areas remained largely unknown during the extensive use of masks and disinfectants. This study investigated the characteristics of bioaerosols in an urban general hospital during the COVID-19 pandemic and found that airborne bacteria and fungi concentrations range from 87±35 to 1037±275 CFU/m and 21±15 to 561±132 CFU/m, respectively, with the outpatient clinic and internal medicine ward showing the highest levels.

View Article and Find Full Text PDF

Household waste-specific ambient air shows greater inhalable antimicrobial resistance risks in densely populated communities.

Waste Manag

January 2025

Shanghai Engineering Research Center of Biotransformation of Organic Solid Waste, School of Ecological and Environmental Science, East China Normal University, Shanghai 200241, PR China; Chongqing Key Laboratory of Precision Optics, Chongqing Institute of East China Normal University, Chongqing 401120, PR China. Electronic address:

Household waste is a hotspot of antibiotic resistance, which can be readily emitted to the ambient airborne inhalable particulate matters (PM) during the day-long storage in communities. Nevertheless, whether these waste-specific inhalable antibiotic resistance genes (ARGs) are associated with pathogenic bacteria or pose hazards to local residents have yet to be explored. By high-throughput metagenomic sequencing and culture-based antibiotic resistance validation, we analyzed 108 airborne PM and nearby environmental samples collected across different types of residential communities in Shanghai, the most populous city in China.

View Article and Find Full Text PDF

Phlorofucofuroeckol-A: A Natural Compound with Potential to Attenuate Inflammatory Diseases Caused by Airborne Fine Dust.

Medicina (Kaunas)

January 2025

Laboratory for Infection Disease Prevention, Korea Zoonosis Research Institute, Jeonbuk National University, Iksan 54531, Republic of Korea.

: Persistent exposure to airborne fine dust (FD) particles contributing to air pollution has been linked to various human health issues, including respiratory inflammation, allergies, and skin diseases. We aimed to identify potential seaweed anti-inflammatory bioactive reagents and determine their effects on systemic inflammatory responses induced by FD particles. : While exploring anti-inflammatory bioactive reagents, we purified compounds with potential anti-inflammatory effects from the seaweed extracts of , , and .

View Article and Find Full Text PDF

Critical mobility in policy making for epidemic containment.

Sci Rep

January 2025

Instituto de Física Interdisciplinar y Sistemas Complejos IFISC (CSIC-UIB), Palma de Mallorca, 07122, Spain.

When considering airborne epidemic spreading in social systems, a natural connection arises between mobility and epidemic contacts. As individuals travel, possibilities to encounter new people either at the final destination or during the transportation process appear. Such contacts can lead to new contagion events.

View Article and Find Full Text PDF

(1) Background: Exposure to blood carries the risk of transmission of many infectious diseases. Healthcare workers (HCWs), including hospital-based medical students, face high and often under-reported rates of exposure to needlestick and sharps injuries. Previous studies have shown that students' knowledge of infection control varies, highlighting the importance of pre-placement training.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!