Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To investigate the agreement between the intraocular pressure (IOP) measurements in the awake condition and under different stages of general inhalational anesthesia using sevoflurane in both glaucomatous and normal children.
Methods: A prospective study was performed on 43 glaucomatous children and 30 age-matched controls. Baseline IOP of one eye was measured immediately before general anesthesia using Perkins tonometer and then re-measured under light, intermediate, and deep anesthesia, and then after intubation. Depth of anesthesia was determined using bispectral index pediatric sensor. The agreement between the IOP measurements before and during different stages of anesthesia was analyzed using Bland-Altman plots. Systematic and proportionate deviations between the IOP measurements were analyzed.
Results: The mean age was 58.6 ± 41.99 months. The mean IOP was significantly lower at all stages of anesthesia in both groups. The coefficient of variation was over 20% in all measurements under anesthesia. For all IOP measurements during anesthesia, the limits of agreement were > 7 mmHg difference in the control group and > 20 mmHg in the glaucomatous group. The best agreement was with the IOP measurement after intubation (mean limit of agreement of -1.4 mmHg, 1.96 s range, -8.8-6 mm Hg) in the control group and with the IOP measurement under intermediate anesthesia (mean limit of agreement of -4.2 mmHg, 1.96 s range, -15.1-6.8 mm Hg) in the glaucomatous group.
Conclusions: Inhalational anesthesia has variable effects on IOP measurement at all stages of anesthesia. Caution should be taken when extrapolating the true IOP from these measurements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10792-021-01800-6 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!