Anaesthesia management during paediatric robotic surgery: preliminary results from a single centre multidisciplinary experience.

Anaesth Crit Care Pain Med

Department of Paediatric Surgery and Urology, Necker-Enfants Malades University Hospital, AP-HP, Centre-Université de Paris, France; Mechanisms and Therapeutic Strategies of Chronic Kidney Disease, INSERM U115-CNRS UMR 8253, Institut Necker Enfants Malades, Département "Croissance et Signalisation", Hôpital Necker Enfants Malades, Université de Paris, 149, Rue de Sèvres, Paris 75015, France.

Published: June 2021

Introduction: Paediatric robotic surgery is gaining popularity across multiple disciplines and offers technical advantages in complex procedures requiring delicate dissection. To date, limited publications describe its perioperative management in children.

Material & Methods: We retrospectively analysed the prospectively collected anaesthetic data of the first 200 robotic-assisted surgery procedures in our paediatric university hospital as part of a multidisciplinary program from October of 2016 to February of 2019. Anaesthetic technique and monitoring were based on guidelines initially derived from adult data. We examined adverse events and particular outcomes including blood loss and analgesic requirements.

Results: Fifty-one different surgical procedures were performed in patients aged 4 months to 18 years (weight 5-144 kg). Operative times averaged 4 h and conversion rate was 3%. Neither robotic arm nor positional injury occurred. Limited access to the patient did not lead to any complication. Hypothermia was frequent and mostly self-limiting. Negative physiological effects due to positioning, body cavity insufflation or surgery manifesting as significant respiratory and haemodynamic changes occurred in 14% and 11% of patients, respectively. Overt haemorrhage complicated one case. Eighty per cent of 170 patients did not require level 3 analgesics postoperatively, while thoracic and certain tumour cases had greater analgesic requirements.

Conclusion: These preliminary results show that paediatric robotic surgery is well tolerated with a low bleeding risk and that major intraoperative events are uncommon. A consistent anaesthetic approach is effective across a broad range of procedures. Analgesic requirements are low excluding thoracic and some complex abdominal cases. Future studies should focus on the rehabilitative aspects of robotic surgery technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.accpm.2021.100837DOI Listing

Publication Analysis

Top Keywords

robotic surgery
16
paediatric robotic
12
surgery
6
robotic
5
anaesthesia management
4
paediatric
4
management paediatric
4
surgery preliminary
4
preliminary single
4
single centre
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!