The measurement of corrected count increment at 1-h post-transfusion (CCI-1 h) of platelet concentrate (PC) transfusion is recommended, but in the revised Japanese Guideline (2017) it was changed to "after 10-min to 1-h", following the revision of the guidelines from Western countries. Here, we aimed to investigate on the feasibility to apply the CCI measured at 10-min or 30-min post-transfusion as the surrogate of CCI-1 h. Peripheral blood was collected at 10-min, 30-min and 1-h post-transfusion of PC and the effectiveness of the transfusion was analyzed based on the CCI. In the period from December 2017 to February 2020, 8 patients, who received multiple PC transfusion (total 208) at our institution, were analyzed. We performed the univariate analyses to examine the relationship between CCI value and the categorical variables, p-value <0.1 was obtained for gender (p = 2.91 × 10), fever after transfusion (p = 0.0163). The qualitative variables, namely measurement time (p = 0.0553), also showed p-value <0.1. Using these factors as covariates in the mixed effect model, we found that the measurement time (p = 0.0007) had a significant effect on the CCI value when looking at fixed effects. Although there is a tendency for decreased CCI values with time progression, the slope of the change in the mixed model was -0.00307, indicating that the CCI difference among the 3 measurements was small. Here we provide evidence that CCI measured at 10-min and 30-min post-transfusion give results comparable to those measured at 1-h post-transfusion, under the Japanese practice of platelet transfusion, which relies on 100 % single-donor apheresis PC, and ABO-identical whenever possible.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.transci.2021.103123DOI Listing

Publication Analysis

Top Keywords

1-h post-transfusion
8
10-min 30-min
8
time cci
4
cci measurement
4
measurement affect
4
affect evaluation
4
evaluation platelet
4
transfusion
4
platelet transfusion
4
transfusion effectiveness?
4

Similar Publications

Acid-base and electrolyte changes in dogs after packed red blood cell transfusion.

Vet Clin Pathol

September 2024

Emergency and Critical Care Service, Fundació Hospital Clínic Veterinari, Universitat Autònoma de Barcelona, Barcelona, Bellaterra, Spain.

Background: Packed RBC (pRBC) transfusions are often necessary to enhance organ perfusion and tissue oxygenation in cases of severe anemia.

Objectives: We aimed to describe changes in acid-base and biochemical parameters in dogs after transfusion of pRBC and potential effects on the outcome.

Methods: The prospective observational study included anemic dogs requiring pRBC transfusions.

View Article and Find Full Text PDF

Background: Platelet radiolabeling with radioisotopes is currently used for human platelet recovery and survival studies. Biotinylation enables ex vivo post-transfusion platelet function testing. Whether platelet biotinylation itself affects platelet function is controversial.

View Article and Find Full Text PDF

This study aims to extend earlier Krogh Cylinder Models of an oxygen profile by considering axial diffusion and analytically solving Fick's Law Partial Differential Equation with novel boundary conditions via the separation of variables. We next prospectively collected a total of 20 animals, which were randomly assigned to receive either fresh or two-week-old stored red blood cell (RBC) transfusions and PQM oxygen data were measured acutely (90 min) or chronically (24 h). Transfusion effects were evaluated in vivo using intravital microscopy of the dorsal skinfold window chamber in Golden Syrian Hamsters.

View Article and Find Full Text PDF

Background: Blood transfusion necessity in neurosurgery varies based on surgical type, blood loss, and patient anemia. Leukocytes in red blood cells (RBCs) component release pro-inflammatory cytokines during storage, contributing to transfusion-related immunomodulation (TRIM). Our aim was to examine the impact of the leukocyte content in transfused PRBCs on patients undergoing neurosurgery for meningioma tumours.

View Article and Find Full Text PDF

Introduction And Objectives: It is challenging to adopt a policy of ABO identical platelet transfusion in hemato-oncological patients because of the high demand. Moreover, there are no global standards for the management of ABO non-identical platelet transfusions due to limited evidence. The current study compared the impact of dose and storage duration of platelets on percent platelet recovery (PPR) at 1 h and 24 h between ABO identical and ABO non-identical platelet transfusions in hemato-oncological conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?