A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intra-aneurysm sac pressure measurement using a thin pressure wire during endovascular aneurysm repair. | LitMetric

Background: An endoleak is a typical complication of endovascular aneurysm repair (EVAR). It is characterized by persistent blood flow between a stent graft and the aneurysm sac. Usually, it can be visualized during primary EVAR, but in many cases, this remains impossible. Therefore, other methods of endoleak assessment are urgently needed. The measurement of aneurysm sac pressure (ASP) seems to be a promising direction of research in this area.

Objectives: We aimed to evaluate the safety and efficacy of a new method for invasive pressure measurement inside the abdominal aortic aneurysm (AAA) during EVAR. We also assessed a correlation between pressure values and early angiographic occurrence of an endoleak after the procedure.

Material And Methods: A total of 20 patients with AAA were included in this experimental prospective study. During EVAR, systolic, diastolic and mean pressure values were recorded both for ASP and aortic pressure (AP) before procedure, after stent graft opening and after final stent graft ballooning.

Results: The measurements were successfully obtained in all participants without any complications. There were no significant differences between all ASP and AP before procedure. After the procedure, blood pressure significantly decreased in the aneurysm sac but not in the aorta. Systolic ASP was significantly lower than systolic AP both after stent graft opening (80.4 ±20.9 mm Hg compared to 110.7 ±21.6 mm Hg, p < 0.01) and after its balloon post-dilatation (65.6 ±26.1 mm Hg compared to 107.4 ±22.1 mm Hg, p < 0.001). Diastolic ASP decreased significantly in comparison to diastolic AP only after stent graft ballooning (48.0 ±14.6 mm Hg compared to 56.4 ±13.6 mm Hg, p < 0.05).

Conclusions: Our study confirmed that the novel method for the measurement of ASP during EVAR, using a thin pressure wire, is feasible and safe.

Download full-text PDF

Source
http://dx.doi.org/10.17219/acem/133425DOI Listing

Publication Analysis

Top Keywords

stent graft
20
aneurysm sac
12
pressure
9
sac pressure
8
pressure measurement
8
thin pressure
8
pressure wire
8
endovascular aneurysm
8
aneurysm repair
8
pressure values
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!