Purpose: QuEnch-assiSTed (QUEST) MRI provides a unique biomarker of excessive production of paramagnetic free radicals (oxidative stress) in vivo. The contribution from superoxide, a common upstream species found in oxidative stress-based disease, to the QUEST metric is unclear. Here, we begin to address this question by measuring superoxide spin-lattice relaxivity (r1) in phantoms.

Methods: Stable superoxide free radicals were generated in water phantoms of potassium superoxide ( . To measure r1, 1/T of different concentration solutions of KO in the presence and absence of the antioxidant superoxide dismutase were measured. The 1/T confounding factors including acquisition sequence, pH, and water source were also evaluated.

Results: The T -weighted signal intensity increased with KO concentration. No contribution from pH, or reaction products other than superoxide, noted on 1/T . Superoxide r1 was measured to be 0.29 mM s , in agreement with that reported for paramagnetic molecular oxygen and nitroxide free radicals.

Conclusion: Our first-in-kind measurement of superoxide free radical r1 suggests a detection sensitivity of QUEST MRI on the order of tens of μM, within the reported level of free radical production during oxidative stress in vivo. Similar studies for other common free radicals are needed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8113059PMC
http://dx.doi.org/10.1002/mrm.28722DOI Listing

Publication Analysis

Top Keywords

superoxide free
12
free radical
12
free radicals
12
superoxide
9
spin-lattice relaxivity
8
quest mri
8
oxidative stress
8
stress vivo
8
free
6
radical spin-lattice
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!