AI Article Synopsis

  • Radius fractures are common but lack standardized treatment protocols; understanding the healing process can improve patient outcomes.
  • High-resolution peripheral quantitative computed tomography (HR-pQCT) allows for detailed monitoring of fractures but is currently limited by time-consuming manual image contouring.
  • A new automated contouring method, 3D morphological geodesic active contours (3D-GAC), shows high accuracy and robustness in analyzing HR-pQCT images of both fractured and intact radii, facilitating better evaluation in clinical settings.

Article Abstract

Radius fractures are among the most common fracture types; however, there is limited consensus on the standard of care. A better understanding of the fracture healing process could help to shape future treatment protocols and thus improve functional outcomes of patients. High-resolution peripheral quantitative computed tomography (HR-pQCT) allows monitoring and evaluation of the radius on the micro-structural level, which is crucial to our understanding of fracture healing. However, current radius fracture studies using HR-pQCT are limited by the lack of automated contouring routines, hence only including small number of patients due to the prohibitively time-consuming task of manually contouring HR-pQCT images. In the present study, a new method to automatically contour images of distal radius fractures based on 3D morphological geodesic active contours (3D-GAC) is presented. Contours of 60 HR-pQCT images of fractured and conservatively treated radii spanning the healing process up to one year post-fracture are compared to the current gold standard, hand-drawn 2D contours, to assess the accuracy of the algorithm. Furthermore, robustness was established by applying the algorithm to HR-pQCT images of intact radii of 73 patients and comparing the resulting morphometric indices to the gold standard patient evaluation including a threshold- and dilation-based contouring approach. Reproducibility was evaluated using repeat scans of intact radii of 19 patients. The new 3D-GAC approach offers contours within inter-operator variability for images of fractured distal radii (mean Dice score of 0.992 ± 0.005 versus median operator Dice score of 0.992 ± 0.006). The generated contours for images of intact radii yielded morphometric indices within the in vivo reproducibility limits compared to the current gold standard. Additionally, the 3D-GAC approach shows an improved robustness against failure (n = 5) when dealing with cortical interruptions, fracture fragments, etc. compared with the automatic, default manufacturer pipeline (n = 40). Using the 3D-GAC approach assures consistent results, while reducing the need for time-consuming hand-contouring.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bone.2021.115930DOI Listing

Publication Analysis

Top Keywords

hr-pqct images
16
gold standard
12
intact radii
12
3d-gac approach
12
fractured distal
8
distal radii
8
geodesic active
8
radius fractures
8
understanding fracture
8
fracture healing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!