Silicone encapsulation of thin-film SiO, SiONand SiC for modern electronic medical implants: a comparative long-term ageing study.

J Neural Eng

Implanted Devices Group, Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, United Kingdom.

Published: April 2021

Ensuring the longevity of implantable devices is critical for their clinical usefulness. This is commonly achieved by hermetically sealing the sensitive electronics in a water impermeable housing, however, this method limits miniaturisation. Alternatively, silicone encapsulation has demonstrated long-term protection of implanted thick-film electronic devices. However, much of the current conformal packaging research is focused on more rigid coatings, such as parylene, liquid crystal polymers and novel inorganic layers. Here, we consider the potential of silicone to protect implants using thin-film technology with features 33 times smaller than thick-film counterparts.Aluminium interdigitated comb structures under plasma-enhanced chemical vapour deposited passivation (SiO, SiON, SiON+ SiC) were encapsulated in medical grade silicones, with a total of six passivation/silicone combinations. Samples were aged in phosphate-buffered saline at 67 C for up to 694 days under a continuous ±5 V biphasic waveform. Periodic electrochemical impedance spectroscopy measurements monitored for leakage currents and degradation of the metal traces. Fourier-transform infrared spectroscopy, x-ray photoelectron spectroscopy, focused-ion-beam and scanning-electron- microscopy were employed to determine any encapsulation material changes.No silicone delamination, passivation dissolution, or metal corrosion was observed during ageing. Impedances greater than 100 GΩ were maintained between the aluminium tracks for silicone encapsulation over SiONand SiC passivations. For these samples the only observed failure mode was open-circuit wire bonds. In contrast, progressive hydration of the SiOcaused its resistance to decrease by an order of magnitude.These results demonstrate silicone encapsulation offers excellent protection to thin-film conducting tracks when combined with appropriate inorganic thin films. This conclusion corresponds to previous reliability studies of silicone encapsulation in aqueous environments, but with a larger sample size. Therefore, we believe silicone encapsulation to be a realistic means of providing long-term protection for the circuits of implanted electronic medical devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8208634PMC
http://dx.doi.org/10.1088/1741-2552/abf0d6DOI Listing

Publication Analysis

Top Keywords

silicone encapsulation
24
silicone
8
sionand sic
8
electronic medical
8
long-term protection
8
encapsulation
6
encapsulation thin-film
4
thin-film sio
4
sio sionand
4
sic modern
4

Similar Publications

Silicon integrated circuits (ICs) are central to the next-generation miniature active neural implants, whether packaged in soft polymers for flexible bioelectronics or implanted as bare die for neural probes. These emerging applications bring the IC closer to the corrosive body environment, raising reliability concerns, particularly for chronic use. Here, we evaluate the inherent hermeticity of bare die ICs, and examine the potential of polydimethylsiloxane (PDMS), a moisture-permeable elastomer, as a standalone encapsulation material.

View Article and Find Full Text PDF

Levofloxacin-loaded silicone contact lenses materials for ocular drug delivery.

J Biomater Appl

December 2024

College of Chemistry and Chemical Engineering, Southeast University, Nanjing, China.

Silicone contact lenses (SCL), as an emerging ocular drug delivery system, achieve controlled drug release. However, the existing drug loading methods have limitations such as low drug uptake, complicated operation process, poor welling rate and transmittance of the lens after drug loading. In this study, an effective microemulsion soaking method was proposed to increase the drug-loading capacity of silicone contact lenses.

View Article and Find Full Text PDF

The eyes play a crucial role in vision and emotional expression, and their loss can profoundly affect appearance and psychological well-being. Eye loss may result from trauma, tumors, infections, malignancies, or congenital abnormalities. Surgical methods for removing an eye include enucleation, evisceration, and exenteration.

View Article and Find Full Text PDF

Fully Stretchable Microbial Fuel Cell with 75% Stretchability.

Small

December 2024

School of Nano Science and Technology, Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou, Jiangsu, 215123, China.

A decent stretchability is of paramount significance to operate microbial fuel cell (MFC) under mechanically dynamic conditions. However, it remains a grand challenge to fabricate fully stretchable MFC without compromising its power output. Here, using Shewanella oneidensis MR-1 (S.

View Article and Find Full Text PDF
Article Synopsis
  • Prolonged sleeping positions can cause health issues like subacromial impingement syndrome and sleep paralysis, prompting studies to analyze the effects of different postures using Fiber Bragg Gratings (FBGs) as sensors.
  • Liquid silicone encapsulated FBG arrays were strategically placed on the body to monitor strain during various sleeping positions, including Supine, Left Fetus, Right Fetus, and Over Stomach.
  • The study found that the FBGs effectively captured swift changes in strain corresponding to different postures, demonstrating their reliability and sensitivity with standard deviations between 0.1 to 0.19.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!