A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Removal of H-decoupling sidebands in CHD C-CEST profiles. | LitMetric

Removal of H-decoupling sidebands in CHD C-CEST profiles.

J Biomol NMR

Department of Structural Biology, St. Jude Children's Research Hospital, Memphis, TN, 38105, USA.

Published: March 2021

A unique aspect of NMR is its capacity to provide integrated insight into both the structure and intrinsic dynamics of biomolecules. Chemical exchange phenomena that often serve as probes of dynamic processes in biological macromolecules can be quantitatively investigated with chemical exchange saturation transfer (CEST) experiments. H-decoupling sidebands, however, always occur in the profiles of CHD C-CEST experiments when using the simple CW (continuous wave) method, which may obscure the detection of minor dips of excited states. Traditionally, these sidebands are manually eliminated from the profiles before data analysis by removing experimental points in the range of H-decoupling field strength ±50 Hz away from the major dips of the ground state on either side of the dips. Unfortunately, this may also eliminate potential minor dips if they overlap with the decoupling sidebands. Here, we developed methods that use pseudo-continuous waves with variable RF amplitudes distributed onto ramps for H decoupling. The new methods were thoroughly validated on Bruker spectrometers at a range of fields (H frequencies of 600, 700, and 850 MHz, and 1.1 GHz). By using these methods, we successfully removed the sidebands from the NMR profiles of CHD C-CEST experiments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8342043PMC
http://dx.doi.org/10.1007/s10858-021-00362-0DOI Listing

Publication Analysis

Top Keywords

chd c-cest
12
h-decoupling sidebands
8
chemical exchange
8
profiles chd
8
c-cest experiments
8
minor dips
8
sidebands
5
removal h-decoupling
4
sidebands chd
4
profiles
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!