A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[VOCs Removal and Emission Monitoring of Beijing Bulk Gasoline Terminals in 2012-2019]. | LitMetric

Bulk gasoline terminals are an important emission source of volatile organic compounds (VOCs) in cities. Beijing started to promote the installation of oil and gas recovery devices at oil storage terminals in 2006 to reduce VOCs emissions, since then VOCs emissions from the terminals have been monitored by the municipal government every year. This paper analyzes the VOCs emission characteristics of oil storage terminals in Beijing from 2012 to 2019. We found that the VOCs import concentration was 165.3 g·m in 2019 and had experienced a decline-rise-decline pattern during 2012-2019. The emission concentration was 7.3 g·m in 2019 and had declined continuously during the preceding eight years. The removal efficiency of VOCs of the gas recovery devices tended to be stable and ranged from 45.5% to 100%. Although the emission concentration had decreased significantly, the removal efficiency of the recovery unit at the oil storage terminals had decreased. Therefore, this paper proposed to strengthen process management, the inspection of the service life of the oil and gas recovery units, and check and maintain records. In addition, the removal efficiency index should be included in the scope of law enforcement and "double index" requirements should be implemented This paper will provide a scientific basis for the future development of atmospheric improvement measures.

Download full-text PDF

Source
http://dx.doi.org/10.13227/j.hjkx.202006244DOI Listing

Publication Analysis

Top Keywords

gas recovery
12
oil storage
12
storage terminals
12
removal efficiency
12
bulk gasoline
8
gasoline terminals
8
oil gas
8
recovery devices
8
vocs emissions
8
g·m 2019
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!