Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Bleeding questionnaires are effective and recommended screening tools for potential bleeding disorder, but healthcare practitioner-administered bleeding assessment tools (expert-ISTH-BATs) are time-consuming. A patient-administered ISTH-BAT (self-ISTH-BAT) has been developed and validated. We translated, validated, and evaluated the usability of self-ISTH-BAT.
Methods: We conducted a forward-backward translation of self-ISTH-BAT from English to Danish. Expert-ISTH-BAT and Danish self-ISTH-BAT were administered to 106 random individuals aged ≥18 years attending Odense University Hospital between August and November 2020 for elective blood sampling. Results comprise a score of bleeding symptoms.
Results: Mean age of included individuals were 49 years (range: 18-83), and 59% were female. Median self-ISTH-BAT score was 2 (range: 0-18) and 1 (range: 0-22) for expert-ISTH-BAT (P = .09). All organ systems had ≥90% exact score agreement between expert-ISTH-BAT and self-ISTH-BAT, except gastrointestinal bleeding (77%) and other bleedings (72%). We found an acceptable correlation (r = .80) between expert-ISTH-BAT and self-ISTH-BAT. The self-ISTH-BAT had 82% sensitivity and 89% specificity at the recommended cutoff for expert-BAT (female:<6; male:<4). At this cutoff, 10 had abnormal self-ISTH-BAT scores with normal expert-ISTH-BAT. Three (3%) had normal self-ISTH-BAT with abnormal expert-ISTH-BAT.
Conclusion: Self-ISTH-BAT can replace expert-ISTH-BAT as a screening tool for bleeding disorders in Danish individuals as only 3% were not identified with the self-ISTH-BAT tool.