Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Fc-glycosylation has crucial impact on the efficacy and safety of IgG-type therapeutic monoclonal antibodies (mAbs). In order to enhance the performance of MS-based bottom-up quantitation strategy, a library of glycopeptide standards containing 26 common IgG1-type Fc-glycoforms has been constructed via modified two-dimensional hydrophilic interaction liquid chromatography (HILIC) purification. Taking advantage of the acquired glycopeptide standards, calibrated quantitation strategy for Fc-glycosylation analysis of mAbs was established and evaluated on the basis of three LC-MS-based methods, including HILIC-MRM (multiple reaction monitoring), HILIC-SIM (selected ion monitor) and RPLC-SIM. Molar concentrations of eleven individual Fc-glycoforms (0.03 ± 0.001-13.77 ± 0.64 nmol mg) as well as degree of fucosylation (75.44-97.04%), galactosylation (3.39-49.47%) and mannosylation (1.12-21.22%) in six IgG1-type mAbs were achieved. In addition, Fc-glycosylation site occupancy was also determined from 98.05% to 99.83%. Compared with traditional MS-based quantitation via peak area normalization, the quantitation accuracy and precision of the calibrated strategy had been remarkably improved, especially when combining with HILIC separation. In addition, the transferability of calibrated quantitation as assessed by using MRM-based method had also been significantly enhanced on different instruments from different laboratories. This calibrated quantitation strategy using glycopeptide standards as calibrators will be useful for Fc-glycosylation analysis of IgG1-type mAbs with multiple glycosylation sites.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2021.338306 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!