A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Using data envelopment analysis and the bootstrap method to evaluate organ transplantation efficiency in Brazil. | LitMetric

Using data envelopment analysis and the bootstrap method to evaluate organ transplantation efficiency in Brazil.

Health Care Manag Sci

COPPEAD Graduate School of Business, Federal University of Rio de Janeiro, Rua Pascoal Lemme, 355 - Cidade Universitária, Rio de Janeiro, RJ, 21941-918, Brazil.

Published: September 2021

Brazil has the most extensive public program for organ transplantation in the world, and the Brazilian National Health System (SUS) provides full coverage of all costs involved in organ donation, transplants, and post-transplant. Despite the relevance of the subject and the shortage of organs for transplants, transplantation process efficiency assessments are still uncommon in Brazil and abroad. This study aims to evaluate the efficiency of the Brazilian states and the Federal District in transforming potential organ donors into actual donations. We applied data envelopment analysis (DEA) in conjunction with the bootstrap technique, using organ transplantation data from 2018. The bootstrap methods applied (bootstrap technique, the bootstrap-biased scores of efficiency, and the bootstrap bias-corrected scores of efficiency) allow to obtain a confidence interval for DEA scores and provide greater robustness to studies based on DEA methodology. The bootstrap bias-corrected model indicates that there is significant room for improvement in terms of converting potential donors into actual donors. The mean corrected score is 0.55, signalizing that altogether the Brazilian states could maximize in 45% the number of transplanted organs without necessarily increasing the pool of potential donors. The study provides insights into the Brazilian processes of organ donation and transplantation, helping to identify locations in need of resource allocation improvements. Given the scarcity of studies with a joint application of DEA and bootstrap techniques in this crucial health activity, we also intend to methodologically contribute to this type of benchmark analysis, emphasizing the importance of considering measurement errors, randomness, and bias at DEA models.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10729-021-09552-6DOI Listing

Publication Analysis

Top Keywords

organ transplantation
12
data envelopment
8
envelopment analysis
8
organ donation
8
brazilian states
8
donors actual
8
bootstrap technique
8
scores efficiency
8
bootstrap bias-corrected
8
potential donors
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!