The emergence of energy spectrum CT provides greater diagnostic value for clinical practice. Its advantage is that it can provide more functional imaging parameters and accurate image information for clinical practice, which represents a mainstream direction of CT technology development at present. This paper mainly studies the clinical trial of CAMPO Precision128 Max ENERGY spectrum CT combined with multiple parameters to evaluate the benign and malignant pleural effusion. This paper analyzes the principle and key performance parameters of energy spectrum CT imaging, the etiology of pleural effusion, and its conventional diagnostic methods and uses energy spectrum CT to detect the benign and malignant pleural effusion. In this paper, two groups of patients with different types of pleural effusions were scanned by line spectrum chest CT scans, and energy spectrum analysis software was used to measure and calculate the CT values of conventional mixed energy values of ROI of patients with pleural effusions. For the CT value and energy curve slope measurement value of different single energy keV, independent sample -test was used to analyze and compare the two sets of data, and finally it has been found out that the two sets of data were similar. According to the experimental results, the curves of energy spectrum of the two groups of data are similar in the descending curve of bow-back. The slope of energy spectrum curve in the leakage group was lower than that in the exudate group, showing statistical significance ( < 0.05). The slope of energy spectrum curve K in the malignant pleural effusion group was significantly higher than that in the benign pleural effusion group, and the difference was statistically significant ( < 0.05). The trend of energy spectrum curves of the two is roughly the same, while at the high energy level, part of the energy spectrum curves of the two are overlapped. The above conclusion indicates that energy spectrum CT plays a certain role in the differential diagnosis of pleural effusion. At the same time, energy spectrum CT also provides a noninvasive and rapid examination method for clinical differentiation of pleural effusion, which has certain clinical application value and prospect.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7935599 | PMC |
http://dx.doi.org/10.1155/2021/5526977 | DOI Listing |
Nat Comput Sci
January 2025
AI for Science (AI4S)-Preferred Program, Peking University Shenzhen Graduate School, Shenzhen, China.
Electronic circular dichroism (ECD) spectra contain key information about molecular chirality by discriminating the absolute configurations of chiral molecules, which is crucial in asymmetric organic synthesis and the drug industry. However, existing predictive approaches lack the consideration of ECD spectra owing to the data scarcity and the limited interpretability to achieve trustworthy prediction. Here we establish a large-scale dataset for chiral molecular ECD spectra and propose ECDFormer for accurate and interpretable ECD spectrum prediction.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Medical Laboratory Technology, Faculty of Applied Health Sciences Technology, Badr University in Cairo (BUC), Badr city, Cairo, Egypt.
Cancer and microbial infections place a significant burden on the world's health systems and can increase the rate of disease and mortality. In the current study, a novel nanocomposite based on Gum Arabic, silver and copper oxide nanoparticles (GA@Ag-CuO nanocomposite) was synthesized to overcome the problem of microbial infection and in cancer treatment. Characterization using UV-Vis.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
Center for Cosmology and Particle Physics, Department of Physics, New York University, New York, New York 10003, USA.
We show that the Veneziano amplitude of string theory is the unique solution to an analytically solvable bootstrap problem. Uniqueness follows from two assumptions: faster than power-law falloff in high-energy scattering and the existence of some infinite sequence in momentum transfer at which higher-spin exchanges cancel. The string amplitude-including the mass spectrum-is an output of this bootstrap.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
Microelectronics Research Center, Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78758, USA.
Theoretical calculations show that twisted double bilayer graphene (TDBG) under a transverse electric field develops a valley Chern number 2 at charge neutrality. Using thermodynamic and thermal activation measurements we report the experimental observation of a universal closing of the charge neutrality gap in the Hofstadter spectrum of TDBG at 1/2 magnetic flux per unit cell, in agreement with theoretical predictions for a valley Chern number 2 gap. Our theoretical analysis of the experimental data shows that the interaction energy, while larger than the flat-band bandwidth in TDBG near 1° does not alter the emergent valley symmetry or the single-particle band topology.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
Center for Theoretical Physics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.
Distinguishing whether a system supports alternate low-energy (locally stable) states-stable (true vacuum) versus metastable (false vacuum)-by direct observation can be difficult when the lifetime of the state is very long but otherwise unknown. Here we demonstrate, in a tractable model system, that there are physical phenomena on much shorter timescales that can diagnose the difference. Specifically, we study the time evolution of the magnetization following a quench in the tilted quantum Ising model, and show that its magnitude spectrum is an effective diagnostic.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!