A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Interaction between sampled rays' defocusing and number on accommodative response in integral imaging near-eye light field displays. | LitMetric

In an integral imaging near-eye light field display using a microlens array, a point on a reconstructed depth plane (RDP) is reconstructed by sampled rays. Previous studies respectively suggested the accommodative response may shift from the RDP under two circumstances: (i) the RDP is away from the central depth plane (CDP) to introduce defocusing in sampled rays; (ii) the sampled ray number is too low. However, sampled rays' defocusing and number may interact, and the interaction's influence on the accommodative response has been little revealed. Therefore, this study adopts a proven imaging model providing retinal images to analyze the accommodative response. As a result, when the RDP and the CDP coincide, the accommodative response matches the RDP. When the RDP deviates from the CDP, defocusing is introduced in sampled rays, causing the accommodative response to shift from the RDP towards the CDP. For example, in a system with a CDP of 4 diopters (D) and 45 sampled rays, when the RDP is at 3, 2, 1, and 0 D, the accommodative response shifts to 3.25, 2.75, 2, and 1.75 D, respectively. With fewer rays, the accommodative response tends to further shift to the CDP. Eventually, with fewer than five rays, the eye accommodates to the CDP and loses the 3D display capacity. Moreover, under different RDPs, the ray number influences differently, and vice versa. An x-y polynomial equation containing three interactive terms is finally provided to reveal the interaction between RDP position and ray number. In comparison, in a pinhole-based system with no CDP, the accommodative response always matches the RDP when the sampled ray number is greater than five.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.417241DOI Listing

Publication Analysis

Top Keywords

accommodative response
36
sampled rays
16
ray number
16
response shift
12
rdp
10
accommodative
9
response
9
sampled rays'
8
rays' defocusing
8
defocusing number
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!