Stable oxime-crosslinked hyaluronan-based hydrogel as a biomimetic vitreous substitute.

Biomaterials

Department of Chemical Engineering and Applied Chemistry, University of Toronto, 200 College St, Toronto, ON, M5S 3E5, Canada; Institute of Biomedical Engineering, University of Toronto, 160 College St, Toronto, ON, M5S 3E1, Canada; Institute of Medical Sciences, University of Toronto, 1 King's College Circle, ON, M5S 1A8, Canada. Electronic address:

Published: April 2021

Vitreous substitutes are clinically used to maintain retinal apposition and preserve retinal function; yet the most used substitutes are gases and oils which have disadvantages including strict face-down positioning post-surgery and the need for subsequent surgical removal, respectively. We have engineered a vitreous substitute comprised of a novel hyaluronan-oxime crosslinked hydrogel. Hyaluronan, which is naturally abundant in the vitreous of the eye, is chemically modified to crosslink with poly(ethylene glycol)-tetraoxyamine via oxime chemistry to produce a vitreous substitute that has similar physical properties to the native vitreous including refractive index, density and transparency. The oxime hydrogel is cytocompatible in vitro with photoreceptors from mouse retinal explants and biocompatible in rabbit eyes as determined by histology of the inner nuclear layer and photoreceptors in the outer nuclear layer. The ocular pressure in the rabbit eyes was consistent over 56 d, demonstrating limited to no swelling. Our vitreous substitute was stable in vivo over 28 d after which it began to degrade, with approximately 50% loss by day 56. We confirmed that the implanted hydrogel did not impact retina function using electroretinography over 90 days versus eyes injected with balanced saline solution. This new oxime hydrogel provides a significant improvement over the status quo as a vitreous substitute.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2021.120750DOI Listing

Publication Analysis

Top Keywords

vitreous substitute
20
vitreous
8
oxime hydrogel
8
rabbit eyes
8
nuclear layer
8
hydrogel
5
substitute
5
stable oxime-crosslinked
4
oxime-crosslinked hyaluronan-based
4
hyaluronan-based hydrogel
4

Similar Publications

Large-scale synthesis of polydimethylsiloxane as vitreous replacement applications.

Des Monomers Polym

January 2025

Department of Physics Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Sumedang, Indonesia.

Polydimethylsiloxane (PDMS) is a polymer that can be used as a vitreous substitute. To fulfill the need for PDMS on a large scale, synthesis of PDMS in a large number is also needed. Therefore, intensive research is needed to produce PDMS in large quantities.

View Article and Find Full Text PDF

Secondary aluminum dross self-heating enhances hazardous waste vitrification.

Waste Manag

December 2024

School of Environmental Science and Engineering, Zhejiang Provincial Key Laboratory of Solid Waste Treatment and Recycling, Zhejiang Engineering Research Center of Non-ferrous Metal Waste Recycling, Zhejiang Gongshang University, Hangzhou, Zhejiang 310012, China. Electronic address:

This study demonstrates the potential of secondary aluminum dross (SAD) to enhance the vitrifying hazardous waste incineration fly ash (FA) and bottom slag (BS). Based on the CaO-SiO-AlO ternary phase diagram, a liquid phase can be achieved at relatively low temperatures by carefully adjusting the AlO content, particularly when the CaO to SiO ratio is around 0.66.

View Article and Find Full Text PDF

Purpose: To evaluate the efficacy of two third-generation resorbable biomaterials-F18 bioglass and β-tricalcium phosphate (β-TCP)-in promoting new bone formation in post-extraction sockets in rats. β-TCP, a synthetic porous ceramic, is well-established in clinical use, while F18 bioglass, a novel silica based bioglass.

Methods: After extraction of the right upper incisor of 45 rats, the sockets were filled either with F18 or β-TCP, or left to naturally fill with a blood clot in control group.

View Article and Find Full Text PDF

Purpose: To analyze endophthalmitis characteristics and risks following a 25-gauge vitrectomy or microincision vitrectomy surgery (MIVS).

Design: Retrospective.

Subjects: Post-MIVS endophthalmitis patients.

View Article and Find Full Text PDF
Article Synopsis
  • - The study examines how a monoclonal antibody (bevacizumab) interacts with silicone oils and hydrogels, revealing that exposure to silicone oils significantly decreases the antibody's functionality and causes aggregation.
  • - Results show that after 24 hours in silicone oil, bevacizumab retains only 30% of its activity, leading to concerns about its clinical use during procedures that involve silicone oil tamponade.
  • - Polysorbate, a common stabilizer, effectively reduces antibody aggregation, while hydrogels do not affect the functionality of the antibodies tested, making them a safer alternative for vitreous body replacement.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!