Analysis of the influence of the facial scanning method on the transfer accuracy of a maxillary digital scan to a 3D face scan for a virtual facebow technique: An in vitro study.

J Prosthet Dent

Associate Professor, Department of Graphic Design and Engineering Projects, Faculty of Engineering Gipuzkoa, University of the Basque Country UPV/EHU, San Sebastian, Spain. Electronic address:

Published: November 2022

Statement Of Problem: With the emergence of virtual articulators, virtual facebow techniques have been developed for mounting maxillary digital scans to virtual articulators. Different scanning methods can be used to obtain 3D face scans, but the influence that these methods have on the accuracy with which a maxillary digital scan is transferred to a 3D face scan is unknown.

Purpose: The purpose of this in vitro study was to analyze the influence of the facial scanning method on the accuracy with which a maxillary digital scan is transferred to a 3D face scan in a virtual facebow technique.

Material And Methods: According to a virtual facebow technique, a maxillary digital scan was transferred to a standard virtual patient-who had the maxillary digital scan in its real location-guided by an intraoral transfer element by using different 3D face scans with the intraoral transfer element in place (reference 3D face scans) obtained with 2 different scanning methods: 10 obtained with an accurate scanning method based on structured white light technology and 10 obtained with a less accurate scanning method based on structure-from-motion technology. For each situation, deviation between the maxillary digital scan at the location obtained via the virtual facebow technique and at its real location was obtained in terms of distance by using a novel methodology. From these distances, the accuracy was assessed in terms of trueness and precision, according to the International Organization for Standardization (ISO) 5725-1. The Student t test with Welch correction was used to determine if the accuracy with which the maxillary digital scan was transferred to the standard virtual patient was influenced by the facial scanning method used to obtain the reference 3D face scans (α=.05).

Results: Significant differences (P<.05) were found among the trueness values obtained when using the different facial scanning methods, with a very large effect size. A trueness of 0.138 mm and a precision of 0.022 mm were obtained by using the structured white light scanning method, and a trueness of 0.416 mm and a precision of 0.095 mm were acquired when using the structure-from-motion scanning method.

Conclusions: The accuracy with which a maxillary digital scan is located with respect to a 3D face scan in a virtual facebow technique is strongly influenced by the facial scanning method used.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2021.02.007DOI Listing

Publication Analysis

Top Keywords

maxillary digital
32
digital scan
28
scanning method
20
virtual facebow
20
accuracy maxillary
16
face scans
16
scan transferred
16
facial scanning
12
face scan
12
facebow technique
12

Similar Publications

Computed Tomographic Anatomy of the Head in Cockatiel (Nymphicus hollandicus).

Vet Med Sci

March 2025

Department of Basic Sciences, Faculty of Veterinary Medicine, Urmia Branch, Islamic Azad University, Urmia, Iran.

Background: Nowadays, computed tomography (CT) scanning is one of the most practical and precise diagnostic imaging methods that can be utilized to evaluate the head in birds.

Objectives: This study aimed to present the normal anatomical data of the head of the cockatiel (Nymphicus hollandicus) using the CT method. In this research, the features of this bird's head were investigated in terms of bones, joints, muscles, sinuses and other constituent tissues.

View Article and Find Full Text PDF

Application of a semi-active robotic system for implant placement in atrophic posterior maxilla: a retrospective case series.

J Dent

January 2025

Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Disease, College of Stomatology, Xi'an Jiaotong University; Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University. Electronic address:

Objective: The study aimed to evaluate the accuracy and safety of the semi-active robotic system for implant placement in atrophic posterior maxilla.

Methods: Patients underwent robot-assisted implant placement in atrophic posterior maxilla were identified and included. Cone-beam computed tomography (CBCT) was performed before surgery.

View Article and Find Full Text PDF

Case 337.

Radiology

January 2025

From the Rush University Medical Center, 1620 W Harrison St, Chicago, IL 60612 (B.H.M., F.G., H.W.A.A., S.G.D., C.D.D., M.A.M.); and University of Texas Health Science Center, Houston, Tex (X.R.Z.).

A 38-year-old previously healthy male patient presented with left-sided facial pain over the prior 5 weeks. He first noticed the pain while washing and applying pressure to his face. The pain was described as shock-like, sharp and shooting, and radiating along the left cheek and temple.

View Article and Find Full Text PDF

A reliable and objective method of measuring soft tissue changes in 2D photographs after distraction osteogenesis in individuals with CL/P.

J Plast Surg Hand Surg

January 2025

Department of Clinical Sciences in Malmö, Lund University, Lund, Sweden; Department of Oral and Maxillofacial Surgery, Skåne University Hospital, Malmö, Sweden; Department of Orthodontics, Malmö University, Malmö, Sweden.

Pre- and postoperative photos to assess results are widely used in plastic and reconstructive surgery, for instance, in patients with cleft lip and palate (CL/P). Evaluations are often performed by assessment panels by viewing the photos. However, these are prone to be subjective.

View Article and Find Full Text PDF

Background/purpose: Identifying crestal bone level (CBL) on the buccal and lingual aspects poses challenges in conventional dental radiographs. Given that optical coherence tomography (OCT) has the capability to non-invasively provide in-depth information about the periodontium, this in vitro study aimed to assess whether OCT can effectively identify periodontal landmarks and measure CBL in the presence of gingiva.

Materials And Methods: An in-house handheld scanning probe connected to a 1310-nm swept-source OCT (SS-OCT) system, along with self-developed algorithms were employed to measure the CBL in dental models with artificial gingiva.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!