Purpose The objective of the current study was to investigate the short-term test-retest reliability of contralateral suppression (CS) of click-evoked otoacoustic emissions (CEOAEs) using commercially available otoacoustic emission equipment. Method Twenty-three young normal-hearing subjects were tested. An otoscopic evaluation, admittance measures, pure-tone audiometry, measurements of CEOAEs without and with contralateral acoustic stimulation (CAS) to determine CS were performed at baseline ( = 23), an immediate retest without and with refitting of the probe (only CS of CEOAEs; = 11), and a retest after 1 week ( = 23) were performed. Test-retest reliability parameters were determined on CEOAE response amplitudes without and with CAS, and on raw and normalized CS indices between baseline and the other test moments. Results Repeated-measures analysis of variance indicated no random or systematic changes in CEOAE response amplitudes without and with CAS, and in raw and normalized CS indices between the test moments. Moderate-to-high intraclass correlation coefficients with mostly high significant between-subjects variability between baseline and each consecutive test moment were found for CEOAE response amplitude without and with CAS, and for the raw and normalized CS indices. Other reliability parameters deteriorated between CEOAE response amplitudes with CAS as compared to without CAS, between baseline and retest with probe refitting, and after 1 week, as well as for frequency-specific raw and normalized CS indices as compared to global CS indices. Conclusions There was considerable variability in raw and normalized CS indices as measured using CEOAEs with CAS using commercially available otoacoustic emission equipment. More research is needed to optimize the measurement of CS of CEOAEs and to reduce influencing factors, as well as to make generalization of test-retest reliability data possible.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1044/2020_JSLHR-20-00393 | DOI Listing |
PLoS One
January 2025
College of Physics and Electronic Engineering, Hainan Normal University, HaiKou, China.
We have successfully prepared a significant number of nanowires from non-toxic silicon sources. Compared to the SiO silicon source used in most other articles, our preparation method is much safer. It provides a simple and harmless new preparation method for the preparation of silicon nanowires.
View Article and Find Full Text PDFNan Fang Yi Ke Da Xue Xue Bao
January 2025
Jiangsu Research Institute of Sports Science, Nanjing 210033, China.
Objectives: To investigate the effect of high glucose on macrophage polarization and the role of immune-responsive gene 1 (IRG1) in mediating its effect.
Methods: RAW264.7 cells were transfected with IRG1-overexpressing plasmid or IRG1 siRNA via electroporation and cultured in either normal or high glucose for 72 h to observe the changes in cell viability and morphology using CCK-8 assay and phase contrast microscopy.
J Pharm Biomed Anal
January 2025
Laboratory of Drug Metabolism and Pharmacokinetics, School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, China. Electronic address:
Radix Rehmanniae (RR) is a widely used herb in traditional Chinese Medicine with properties of tonifying the kidneys and nourishing the blood. Both raw and processed RR are effective for the treatment of diabetes in clinical practice. Oligosaccharides and iridoid glycosides are the primary active components responsible for the anti-diabetic effects of RR.
View Article and Find Full Text PDFACS Nano
January 2025
Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital School of Medicine, Shanghai Jiao Tong University, Shanghai 200011, China.
Lymphedema, a severe and complex inflammatory disease caused by lymphatic system insufficiency and impeded lymphatic drainage that causes an enormous physical and psychological burden on patients and may even lead to death, has long been a challenging issue in the medical field. Clinically, conventional approaches including surgical treatment and conservative treatment have been employed for lymphedema therapy, but their curative effect is still unsatisfactory because of high operational difficulty, high cost, and long-term reliance. In this study, a novel kind of piezoelectric microneedle driven by ultrasound (US) is proposed to regulate macrophage polarization and remodel the pathological inflammatory microenvironment in a noninvasive manner, thereby promoting lymphatic regeneration and improving lymphedema.
View Article and Find Full Text PDFPhytomedicine
January 2025
Department of Integrative Biotechnology, and Biomedical Institute for Convergence at SKKU, Sungkyunkwan University, Suwon 16419, Republic of Korea; Department of Biocosmetics, Sungkyunkwan University, Suwon 16419, Republic of Korea. Electronic address:
Background: Inflammation is the body's innate reaction to foreign pathogens and serves as a self-regulating mechanism. However, the immune system can mistakenly target the body's own tissues, triggering unnecessary inflammation. For millennia, medicinal plants have been employed for the treatment of diseases.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!