Conjunctival sac stenosis is the contraction of the conjunctival sac as a result of trauma or disease. The aim of the present study was to observe the clinical effects of low-level laser therapy (LLLT) combined with hydroxyapatite (HA) orbital implantation as a treatment strategy for conjunctival sac stenosis. A total of 10 patients with conjunctival sac stenosis were treated with scleral graft transplantation in conjunction with HA implantation and postoperative LLLT. In addition, a rabbit model was used to investigate the biological mechanism underlying the effects of LLLT with the aim of preventing and treating orbital implantation exposure. The right eyeball was removed, orbital implantation performed and LLLT applied to experimental groups. Tc-Methyl diphosphonate scanning methods were performed at different timepoints to compare the average radioactivity count of the region of interest between surgical (right) and control (left) eyes (R/L). Histopathological examination was performed 8 weeks post-surgery, followed by analysis of fiber vascularization. Following LLLT, moderate conjunctival wounds were completely healed within 2 weeks and severe stenosis wounds healed within 3 weeks. Following prosthesis implantation in the rabbit model, a significantly elevated R/L ratio was observed after 4 weeks, whereas no significant difference was observed compared with the control group at 6 and 8 weeks postoperatively. Histopathological examination revealed that all implants were fibrotic. Overall, the present study demonstrated that LLLT promoted the survival of conjunctival grafts, stimulated conjunctival incision healing and promoted early vascularization of HA implants. Clinical trial registration no: ChiCTR-DDT-12002660 (www.chictr.org/cn/).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7885064 | PMC |
http://dx.doi.org/10.3892/etm.2021.9745 | DOI Listing |
Ophthalmic Plast Reconstr Surg
January 2025
Department of Ophthalmology, Tufts University School of Medicine, Boston, Massachusetts, U.S.A.
Purpose: To employ a validated survey for evaluation of quality of life (QoL) outcomes and associated factors in a US cohort of adult patients with acquired anophthalmia wearing a prosthesis.
Methods: A retrospective cohort study was performed at a single, US academic institution of patients cared for between 2012 and 2021. The electronic medical record database was queried for adult patients with a history of evisceration or enucleation surgery and placement of an orbital implant.
Indian J Plast Surg
December 2024
Department of Plastic Surgery, Grant Government Medical College and Sir J. J. Group of Hospitals, Byculla, Mumbai, Maharashtra, India.
Chin augmentation can dramatically transform a patient's appearance. Various techniques are in use, each with their specific problems and limitations. We present the first case report from the Indian subcontinent using a custom 3D-printed, bioresorbable polycaprolactone implant.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
December 2024
South China University of Technology, School of Chemistry and Chemical Engineering, Wushan St., 510640, Guangzhou, CHINA.
Electroreduction of CO2 to CO represents a highly promising way for artificial carbon cycling, but obtaining high selectivity over a wide potential window remains a challenge due to the sluggish CO generation and diffusion kinetics. Here we report an integration of long-range P modified asymmetrical bismuth atomic site on an ordered macroporous carbon skeleton with mesoporous "wall" (MW-BiN3-POMC) for efficient electroreduction of CO2. In-depth in-situ investigations with theoretical computations reveal that the incorporation of long-range P atom is able to strengthen the orbital interaction between the C 2p of CO2 and Bi 6p, thereby establishing an electronic transport bridge for the activation of CO2 molecule.
View Article and Find Full Text PDFJ Stomatol Oral Maxillofac Surg
December 2024
Face Ahead® Surgicenter, Belgium and Ziekenhuis aan de Stroom, Campus GZA, B-2018, Antwerp, Belgium. Electronic address:
Objective: This expert opinion presents provisional guidelines for addressing complications associated with Additively Manufactured Subperiosteal Jaw Implants (AMSJI®) in patients with severe maxillary atrophy. AMSJI®'s custom design, supported by finite element analysis (FEA), allows precise placement that avoids critical anatomical structures and minimizes complications relative to alternative solutions.
Materials And Methods: Data were gathered through firsthand experiences, direct communications, and insights from international workgroup meetings.
Int J Mol Sci
November 2024
Department of Ophthalmology, Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania.
Reconstructing the orbit following complex craniofacial fractures presents significant challenges. Throughout the years, several materials have been used for orbital reconstruction, taking into account factors such as their durability, compatibility with living tissue, cost efficiency, safety, and capacity to be adjusted during surgery. Nevertheless, a consensus has not yet been reached on the optimal material for orbital restoration.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!