A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation and Comparison of Left Ventricular Functions by Cardiac MRI and 2D Transthoracic Echocardiography. | LitMetric

AI Article Synopsis

  • The study focused on accurately measuring left ventricular function (LVF) using different methods in cardiac MRI and comparing them to transthoracic echocardiography (TTE).
  • It involved 31 patients with left ventricular dysfunction, where LVF parameters were calculated using both a short axis method and a combined method in MRI.
  • The results showed that the short axis method had a better correlation with TTE measurements, suggesting it is a more reliable approach for evaluating left ventricular dysfunction.

Article Abstract

Objective: It is important to measure left ventricular function (LVF) accurately in the diagnosis and follow-up of cardiovascular diseases. Different imaging algorithms and mathematical calculations have been developed for the evaluation of LVF in cardiac magnetic resonance imaging (MRI), and numerous studies are still being carried on this. In our study, LVF was calculated by two different measurement methods in MRI and were compared with transthoracic echocardiography (TTE) to assess the correlation and the consistency of these with TTE.

Materials And Methods: In this study, 31 patients with left ventricular dysfunction due to different etiologies were evaluated with simultaneous TTE and MRI. In the Cine MR images, LVF parameters of ejection fraction, end-diastolic volume, end-systolic volume, and myocardial mass were measured using short axis images (short axis method) and short axis plus four chamber and two chamber images (combined method). The results were compared with the results from TTE.

Results: We found that the combined and the short axis-based calculations of ejection fraction, end-diastolic volume, end-systolic volume, and myocardial mass in cardiac MRI showed correlation and consistency with those calculated via echocardiography. We also determined that the short axis-based calculations in cardiac MRI showed better correlation with the echocardiography compared with the combined method.

Conclusion: Because our results revealed that the cardiac MRI results obtained from the short axis method better correlate with the TTE, we recommend using short axis-based measurements in the evaluation left ventricular dysfunction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7929590PMC
http://dx.doi.org/10.5152/eurasianjmed.2021.20038DOI Listing

Publication Analysis

Top Keywords

left ventricular
16
cardiac mri
16
short axis
16
short axis-based
12
transthoracic echocardiography
8
correlation consistency
8
ventricular dysfunction
8
ejection fraction
8
fraction end-diastolic
8
end-diastolic volume
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!