A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of a software for semi-automatically calculating the bone scan index on bone scintigraphy scans. | LitMetric

Assessment of a software for semi-automatically calculating the bone scan index on bone scintigraphy scans.

Clin Imaging

Department of Nuclear Medicine, Graduate School of Medicine, Osaka City University, 1-4-3, Asahimachi, Abeno-ku, Osaka-City, Osaka-Fu 545-8585, Japan. Electronic address:

Published: October 2021

Aims: The incidence of bone metastases exceeds 85% in patients who die from prostate cancer. Bone scintigraphy is the most widely used method for the early detection of bone metastases in prostate cancer. We developed a software program that semi-automatically calculated the bone scan index (BSI) on technetium-99m hydroxymethylene diphosphonate bone scintigraphy scans with a computer-aided diagnosis system (CAD) and examined whether the BSI calculated using this software could replace the extent of disease (EOD) score.

Methods: The subjects were 175 patients who were diagnosed with prostate cancer at our hospital and underwent bone scintigraphy. We analyzed receiver operating characteristic curves to determine the BSI cutoff value between EOD groups. The cutoff value was determined based on the maximum value of the sum of the sensitivity and specificity.

Results: BSI cutoff values of 0.20, 1.56, and 4.56 were used to distinguish between EOD 0 and 1-4 (sensitivity [87.2%] and specificity [100.0%]), between EOD 0- and 2-4 (sensitivity [85.2%] and specificity [92.0%]), and between EOD 0-2 and 3-4 (sensitivity [88.4%] and specificity [99.2%]), respectively.

Conclusion: Our results suggest that this software can calculate BSI, and the software may play a role in predicting prognosis and selecting an appropriate treatment strategy. If a sufficient number of other nuclear medicine tests are performed, creating a similar CAD system is possible.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinimag.2020.12.016DOI Listing

Publication Analysis

Top Keywords

bone scintigraphy
16
prostate cancer
12
bone
8
bone scan
8
scintigraphy scans
8
bone metastases
8
bsi cutoff
8
bsi
5
eod
5
assessment software
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!