Introduction: Robotic surgery has proven effective in certain surgical procedures. However, in liver and pancreatic surgery (HBP) its use is still rare. The initial experience in HBP robotic surgery of a specialized unit of a tertiary hospital is presented.

Method: The results of patients undergoing robotic HBP surgery between April 2018 and October 2020 have been prospectively studied. The data analyzed correspond to demographic data, surgical techniques performed, associated morbidity and mortality.

Results: 64 patients were operated, corresponding to 35 hepatectomies (major [6.7%], anatomic [52.9%], limited [34.4%], cystectomies [3%] and marsupialization [3%]), 29 pancreatectomies (distal [48.2%], central [6.9%], cephalic [13.8%], enucleations [24.1%], ampullectomies [3.5%] and duodenal resections [3.5%]). In liver surgery the mean operative time was 204.4 minutes (100-265 min), the median postoperative complications according to the Clavien-Dindo scale was one (1-4), the mean blood losses 166.7 mL (100-300 mL), there was no conversion and the mean postoperative stay was four days (2-14 days). In pancreatic surgery, the mean operative time was 243.8 minutes (125-460 min), the median of postoperative complications was two (1-4), blood loss of 202.3 mL (100-500 mL) associated to a conversion rate 17.8% and an average stay of seven days (3-23 days).

Conclusions: Robotic HBP surgery is safe and feasible. It is suggested that its use facilitates parenchymal sparing surgery, access to posterior liver segments and anastomosis in pancreatic reconstruction compared to laparoscopic surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ciresp.2021.01.009DOI Listing

Publication Analysis

Top Keywords

robotic surgery
12
surgery
10
liver pancreatic
8
specialized unit
8
pancreatic surgery
8
robotic hbp
8
hbp surgery
8
surgery operative
8
operative time
8
median postoperative
8

Similar Publications

Robotic bronchoscopy: Evolution of advanced diagnostic technologies for pulmonary lesions.

Best Pract Res Clin Anaesthesiol

March 2024

1400 Holcombe Blvd, FC 13.2000, Houston, TX, 77030, USA. Electronic address:

Lung cancer is among one of the most commonly diagnosed malignancies and is the leading cause of cancer-related mortality in both men and women globally, with an estimated 1.8 million deaths annually. Moreover, it is also the leading cause of cancer related deaths in the United States (U.

View Article and Find Full Text PDF

Background: The emergence of telesurgery has received global interest, with secure network transmission identified as a crucial determinant of its success. This study aimed to evaluate the safety and viability of employing quantum cryptography communication in remote partial nephrectomy.

Methods: The surgeon operated on the patient from a distance of over 260 km using remote control of a surgical robot.

View Article and Find Full Text PDF

Robotic Resection of an Ectopic Parathyroid Gland: A Systematic Review.

Cureus

December 2024

General Surgery, East Sussex Healthcare NHS Trust, Brighton and Hove, GBR.

Ectopic parathyroid glands result from abnormal migration during development. If not detected promptly, they can lead to persistent or recurrent primary hyperparathyroidism (pHPT). Inferior parathyroid glands are typically located in the anterior mediastinum, while superior parathyroid glands are often near the tracheoesophageal groove, both of which contribute to pHPT.

View Article and Find Full Text PDF

Objective: Our aim is to determine the comparative effectiveness of unimodality organ preservation surgery versus radiotherapy on oncological and functional outcomes in patients with early hypopharyngeal cancer.

Introduction: Early hypopharyngeal cancer is difficult to detect and therefore rarely diagnosed, as patients are often asymptomatic. Radiotherapy is considered the main treatment, although this modality has been compared to the previously used open surgical approach, which may not reflect current surgical options.

View Article and Find Full Text PDF

Controlling of Applied Force and Cornea Displacement Estimation in Robotic Corneal Surgery With a Gripper Surgical Instrument.

Int J Med Robot

February 2025

Faculty of Health, Education, Medicine and Social Care, Medical Technology Research Centre, The Institute of Excellence in Robotic Surgery, Anglia Ruskin University, Chelmsford, UK.

Background: The human eye consists of highly sensitive, hydrated, and relatively thin tissues, making precise control and accurate force estimation crucial in robotic eye surgery. This paper introduces a novel control method and state observer designed for a gripper surgical instrument used on the external ocular surface during robotic eye surgery.

Methods: A novel state observer, operating in tandem with the controller, estimates the applied force.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!