Aims: Previous studies have already shown early proximal ingrowth, fast osseous integration, and a stable fit of the uncemented Symax hip stem, with excellent clinical and radiographic performance. Aims were to evaluate cumulative revision rates and reasons for revision of the Symax hip stem using Dutch Arthroplasty Register (LROI) data and to assess possible associations between patient characteristics and revision rate of the Symax hip stem.

Patients And Methods: All total hip arthroplasties with the uncemented Symax hip stem registered in the LROI between 2007 and 2017 were included (n = 5,013). Kaplan-Meier survival analysis was performed to assess the cumulative 1, 5 and 7-year revision percentages. Cox proportional hazard regression analysis was performed to assess the association between patient and procedural characteristics, and revision arthroplasty of the stem.

Results: Cumulative 1, 5, and 7-year revision rates (with 95% confidence interval (CI)) for revision of any component were 1.5% (CI 1.2%-1.8%), 3.2% (CI 2.7%-3.7%), and 3.8% (CI 3.1%-4.4%) respectively. Cumulative 1, 5, and 7-year stem revision rates of the Symax hip stem were 0.9% (CI 0.6%-1.1%), 1.5% (CI 1.1%-1.9%), and 1.7% (CI 1.3%-2.1%) respectively. Periprosthetic fractures (n = 35) and loosening of the stem (n = 30) were the most common reasons for revision of the stem. Revision of the stem was associated with acute fracture as primary diagnosis (Hazard Ratio (HR) 2.4 (CI 1.3-4.3)), or history of a previous surgery to the affected hip (HR 2.7 (CI 1.4-5.2)).

Conclusion: This population-based registry study shows revision rates for the Symax hip stem comparable to those for best performing uncemented total hip arthroplasties in the Netherlands. Primary diagnosis of an acute fracture, and history of previous surgery on the affected hip, were significantly associated risk factors for revision of the Symax hip stem, and we discourage the use of the Symax hip stem in these patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7954353PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0248483PLOS

Publication Analysis

Top Keywords

symax hip
36
hip stem
32
revision rates
16
revision
13
hip
13
reasons revision
12
uncemented symax
12
stem
12
cumulative 7-year
12
symax
9

Similar Publications

Aims: Previous studies have already shown early proximal ingrowth, fast osseous integration, and a stable fit of the uncemented Symax hip stem, with excellent clinical and radiographic performance. Aims were to evaluate cumulative revision rates and reasons for revision of the Symax hip stem using Dutch Arthroplasty Register (LROI) data and to assess possible associations between patient characteristics and revision rate of the Symax hip stem.

Patients And Methods: All total hip arthroplasties with the uncemented Symax hip stem registered in the LROI between 2007 and 2017 were included (n = 5,013).

View Article and Find Full Text PDF

Background and purpose - The uncemented Symax hip stem has shown early proximal ingrowth as result of the BONIT-hydroxyapatite (HA) coating and the distal DOTIZE surface treatment. We evaluated 2-year postoperative radiostereometric analysis (RSA) migration of the Symax hip stem in THA patients. We also investigated the correlation between migration at 4 weeks and clinical outcomes after 2 years.

View Article and Find Full Text PDF

Background: The uncemented Symax hip stem is developed through optimization of the uncemented Omnifit hip stem. The Symax stem design combines an anatomical anteverted proximal geometry with a straight distal section. The proximal part is coated with a biomimetic hydroxyapatite (HA) coating for improved osseointegration to enhance load transfer and to minimize proximal bone loss.

View Article and Find Full Text PDF

Up to 10-year follow-up of the Symax stem in THA: a Danish single-centre study.

Hip Int

July 2018

Section for Hip and Knee Replacement, Department of Orthopaedic Surgery, Vejle Hospital, Vejle, Denmark.

Introduction: The design of the cementless Symax-HA femoral stem is based on geometrical analysis of human femoral anatomy to optimise the fit within the femur. The stem combines an anatomical proximal section enabling a metaphyseal anchorage with a straight distal section. This results in an improved proximal load transfer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!