Intra-prosthetic dislocation of the dual-mobile acetabular cup is a rare complication. Most often, it is the result of wear of the polyethylene liner. It can also occur during a closed reduction of a dislocated dual-mobile cup. It is extremely important to recognize this complication immediately in order to avoid the consequences. This paper presents the first case of iatrogenic intraprosthetic dislocation at the Traumatology and Orthopaedics Department of the Military Medical Institute, our management of the case and suggestions for treating patients with a dislocation of the dual-mobile acetabular cup.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5604/01.3001.0014.7568 | DOI Listing |
Arthroplast Today
February 2025
Department of Orthopaedic Surgery, Fiona Stanley Fremantle Hospitals Group, Murdoch, Western Australia, Australia.
Background: Dual mobility (DM) implants in total hip arthroplasty provide excellent range of motion with low dislocation rates. A complication of this design is intraprosthetic dislocation (IPD), where the polyethylene (PE) liner dissociates from the femoral head. In older designs, IPD occurred due to a small head size and late PE wear with head-capture-mechanism failure.
View Article and Find Full Text PDFBone Joint J
May 2024
Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA.
Aims: Dual-mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a rare complication of DM that is believed to have decreased with contemporary implants. This study aimed to report incidence, treatment, and outcomes of contemporary DM IPD.
View Article and Find Full Text PDFEur Heart J Case Rep
February 2024
Cardiology Department, Virgen del Rocío University Hospital, Manuel Siurot, s/n, Seville 41013, Spain.
Background: Ventricular septal defect (VSD) is an unusual complication of transcatheter aortic valve implantation (TAVI). The risk factors are not well understood but may include oversizing, calcification amount and location, left-ventricular chamber morphology, and valve-in-valve (ViV) procedures. Percutaneous treatment is challenging but is usually the preferred option.
View Article and Find Full Text PDFRadiol Case Rep
November 2023
Loyola University Medical Center and Loyola University Chicago, 2160 S First Ave, Maywood, IL, 60153, USA.
Dual-mobility total hip arthroplasties were developed to decrease the risk of dislocation and instability seen with traditional fixed-bearing total hip arthroplasties. However, dual-mobility constructs, notably the first-generation design, come with a risk of intraprosthetic dislocation (IPD). These dislocations occur when the polyethylene femoral head component is dislodged, causing direct articulation between the inner ceramic femoral head and the metal acetabular shell.
View Article and Find Full Text PDFBMJ Case Rep
March 2022
T&O, Royal Cornwall Hospitals NHS Trust, Truro, Cornwall, UK.
We describe the first intraprosthetic dislocations of a 22 mm head in a dual mobility hip replacement in the literature. This case emphasises the importance of information gathering and planning when dealing with arthroplasty complications. Furthermore, it highlights the necessity of adequate muscle relaxation and analgesia when dealing with hip dislocations.