This study aimed to compare performance on sand and a firm surface and to describe the physical capacity of male and female beach soccer players. Sixty-six male and 29 female competitive beach soccer players voluntarily participated in this study. Firstly, within-subjects test scores were compared to scores on a firm surface (criterion validity; = 15 men) and reconducted on a second occasion (reliability; = 51 men). Secondly, the best score on sand was retained to compare test performance between ages (classified as below 20, 20-30, and above 30 years) and sexes. Performance assessments included sprint time over 5 and 15 m (once on a firm surface and twice on sand), standing long jump (SLJ, once on a firm surface and twice on sand) and Yo-Yo intermittent recovery level 1 (Yo-Yo IR1, once on a firm surface and once on sand; only data for men were available). Five-m sprint and Yo-Yo IR1 performance on sand were not correlated to performance on a firm surface ( > 0.05). Test-retest reliability was acceptable for the 15-m sprint and SLJ tests (ICC > 0.90; CV < 5%). Performance in 15-m sprint and maximal sprinting speed were moderately lower in male players aged above 30 years. compared to players aged below 30 years ( = 0.35-0.42; < 0.05). Irrespective of the age group, weight-bearing power-based performance mass was moderately to very largely higher in male players than in female players ( = 0.42-0.88; < 0.05). The lack of a consistent relationship between performance on sand and on a firm surface might indicate the need to develop specific test batteries for sand-based athletes. Age-related differences in physical performance were evident only in sprint capacity. Further studies are warranted to elucidate our preliminary findings and to develop the sand specific tests.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7940533 | PMC |
http://dx.doi.org/10.3389/fspor.2021.636308 | DOI Listing |
Sensors (Basel)
December 2024
College of Material Science and Technology, Beijing Forestry University, Beijing 100083, China.
Mattress firmness is a critical factor influencing sleep quality. This study investigates the effects of time, mattress firmness, and anthropometric parameters on surface electromyographic (sEMG) activity during supine rest. Eleven participants were analyzed, and the values for lower back sEMG on three mattresses were measured as 8.
View Article and Find Full Text PDFJ Craniofac Surg
January 2025
Department of Oral Biology, Division in Anatomy and Developmental Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry.
This narrative review explores the various injection techniques utilized in facial filler procedures, emphasizing their applications, benefits, and potential complications. The increasing demand for total facial contouring and rejuvenation has led to a rise in the use of volumizing fillers and the integration of these procedures with other treatments such as toxins, threads, lasers, radiofrequency, and ultrasound. Achieving satisfactory results necessitates a comprehensive understanding of facial anatomy and the effects of aging on skin tissue.
View Article and Find Full Text PDFSkinmed
January 2025
Dermatology Department, Miguel Servet Hospital, IIS Aragon, Zaragoza University, Zaragoza, Spain.
A 63-year-old man, with no past medical history, presented with an asymptomatic, progressively evolving polypoid lesion for 2 years in the left ciliary region. Physical examination revealed an exophytic tumor lesion of firm consistency and lobulated surface, with regular and well-defined borders. It measured 2 cm in diameter, and had a brownish-violet coloration with whitish areas (Figure 1).
View Article and Find Full Text PDFJ Appl Biomech
January 2025
College of Medicine, The Pennsylvania State University, Hershey, PA, USA.
Nat Commun
December 2024
Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Translational Research Institute of Brain and Brain-Like Intelligence, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai, China.
Penetrating orocutaneous or oropharyngeal fistulas (POFs), severe complications following unsuccessful oral or oropharyngeal reconstruction, remain complex clinical challenges due to lack of supportive tissue, contamination with saliva and chewed food, and dynamic oral environment. Here, we present a Janus hydrogel adhesive (JHA) with asymmetric functions on opposite sides fabricated via a facile surface enzyme-initiated polymerization (SEIP) approach, which self-entraps surface water and blood within an in-situ formed hydrogel layer (RL) to effectively bridge biological tissues with a supporting hydrogel (SL), achieving superior wet-adhesion and seamless wound plugging. The tough SL hydrogel interlocked with RL dissipates energy to withstand external mechanical stimuli from continuous oral motions like chewing and swallowing, thus reducing stress-induced damage.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!