This study aimed to investigate the effects of systemic propranol on the osseointegration of titanium implants. After the surgical insertion of titanium implants into the metaphyseal part of the tibial bone, the rats were randomly divided into 2 equal groups: the control (CNT) (n = 10) and propranol group (P) (n = 10); CNT: Rats received no further treatment during the 4 week experimental period after surgery. Rats received 10 mg/kg propranol in every day during the 4 week experimental period in PRP group after the surgical insertion of the implants. After the experimental period, the rats were euthanized, blood serum were collected to biochemical analysis and the implants and surrounding bone tissues were used for the histopathologic analysis. To analysis of the data between tests and controls student T test was used. There were no significant differences in the biochemical parameters (alcaline phosphatase, calcium, phosphor) of the groups (P > 0.05). Bone implant connection (BIC) ratios was detected higher in test animals compared with the controls (P < 0.05). Systemic propranolol may increases titanium implant osseointegration.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000006857DOI Listing

Publication Analysis

Top Keywords

titanium implants
12
experimental period
12
osseointegration titanium
8
surgical insertion
8
rats received
8
week experimental
8
implants
5
evaluation effects
4
effects ß-adrenergic
4
ß-adrenergic receptor-propranolol
4

Similar Publications

A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus.

Sci Rep

January 2025

Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.

In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy).

View Article and Find Full Text PDF

Long-Term Natural Hydroxyapatite and Synthetic Collagen Hydroxyapatite Enhance Bone Regeneration and Implant Fixation Similar to Allograft in a Sheep Model of Implant Integration.

Calcif Tissue Int

January 2025

Orthopaedic Research Laboratory, Department of Orthopedic Surgery and Traumatology, Odense University Hospital & Department of Clinical Research, University of Southern Denmark, V18-812B-1, Etage 1, Bygning 45.4, Nyt Sund, SDU Campus 5230, Odense, Denmark.

There is an increasing demand for a suitable bone substitute to replace current clinical gold standard autografts or allografts. Majority of previous studies have focused on the early effects of substitutes on bone formation, while information on their long-term efficacies remains limited. This study investigated the efficacies of natural hydroxyapatite (nHA) derived from oyster shells and synthetic hydroxyapatite mixed with collagen (COL/HA) or chitosan (CS/HA) on bone regeneration and implant fixation in sheep.

View Article and Find Full Text PDF

Objectives: Re-operations due to material degeneration carry a burden for patients with congenital heart disease (CHD). The study aim was to compare rapid vs. slow degeneration of biomaterials in CHD patients.

View Article and Find Full Text PDF
Article Synopsis
  • Rotator cuff tears and Bankart lesions can greatly impact shoulder function, and arthroscopic repairs using new suture anchors like Sironix show promise for improving outcomes.
  • A study involving 60 participants demonstrated no repair failures and significant functional improvement following surgery with Sironix devices, assessed using various validated scoring scales.
  • Overall, the results indicate that Sironix suture anchors are safe and effective in treating shoulder injuries, maintaining high patient satisfaction and functional recovery.
View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the impact of a metal artifact reduction (MAR) algorithm on cone-beam computed tomography (CBCT) scans of titanium and zirconia implants, both within and outside the field of view (FOV).

Materials And Methods: In this study, a dry human mandible was positioned in a CBCT scanner with only its left quadrant included in the FOV. Each type of implant (titanium and zirconia) was placed once in the right second premolar extraction socket and once in the left second premolar extraction socket of the mandible.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!