A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of radiopacities of CAD/CAM restorative materials and resin cements by digital radiography. | LitMetric

Evaluation of radiopacities of CAD/CAM restorative materials and resin cements by digital radiography.

Clin Oral Investig

Department of Computer Programming, Vocational School of Technical Sciences, Ordu University, Ordu, Turkey.

Published: October 2021

Objective: This study aims to compare the radiopacities of computer-aided design/computer-aided manufacture (CAD/CAM) blocks and the adhesive cements used for their bonding.

Materials And Methods: 1 ± 0.2 mm thick specimens were obtained from six different CAD/CAM blocks (Incoris TZI, IPS e.max CAD, Vita Mark II, Cerasmart, Vita Enamic, and Vita Suprinity), four different adhesive resin cements (Panavia F2.0, Variolink Esthetic DC, RelyX Unicem Aplicap, G-CEM LinkAce), and a tooth. Radiographs of the specimens from each group, a tooth section, and an aluminum (Al) step-wedge were acquired. The radiopacity values of the materials were calculated as equivalents of Al thickness using the gray level values. The data were statistically analyzed using one-way ANOVA and Tukey HSD tests.

Results: All the materials except Cerasmart and Vita Enamic had significantly higher radiopacity values than dentin (p < 0.05). Of the assessed blocks, the highest radiopacity value was observed in Incoris TZI, and the lowest radiopacity value was observed in Vita Enamic. Variolink Esthetic DC and RelyX Unicem Aplicap showed significantly higher radiopacity (p < 0.05) than the other adhesive cements, including enamel and dentin.

Conclusions: In this study, the majority of the CAD/CAM materials and all the adhesive resin cements were found to have sufficient radiopacity for prosthetic restorations according to the criteria set by the International Organization for Standardization (ISO).

Clinical Relevance: From a clinical and biological point of view, materials should be chosen according to their radiopacity and other properties, such as biocompatibility and esthetics. If the selected restorative CAD/CAM blocks have a radiopacity value less than or equal to dentin, cements with higher radiopacity values are recommended to facilitate radiological diagnoses for periphery and interface of restorations.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-021-03875-yDOI Listing

Publication Analysis

Top Keywords

resin cements
12
cad/cam blocks
12
vita enamic
12
radiopacity values
12
higher radiopacity
12
radiopacity
9
adhesive cements
8
incoris tzi
8
cerasmart vita
8
adhesive resin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!