This paper adopted an approximation of a melting plateau to solve the problem that temperature data cannot be monitored continuously when measuring the spectral irradiance of a large area tungsten carbide-carbon high-temperature fixed-point blackbody at each measured wavelength. Tests with fully measured curves showed that the method has a rather small deviation from the measured data of 0.017 K maximum, which corresponds to the spectral irradiance deviation of 0.005% at 500 nm. The maximum relative deviation between the Akima fitting method and the measured temperature in terms of spectral irradiance was 0.002%, which was better than -0.067 of a single temperature of 3020.11 K method and 0.026% of a linear interpolation method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.409631 | DOI Listing |
ACS Sens
January 2025
College of Chemistry, Jilin Province Research Center for Engineering and Technology of Spectral Analytical Instruments, Jilin University, Changchun 130012, China.
Superior to traditional multiplex photoelectrochemical (PEC) sensors, integrated multitarget assay on a single reconstructive electrode interface is promising in real-time detection through eliminating the need of specialized instrumentation and cumbersome interfacial modifications. Current interface reconstruction approaches including pH modulation and bioenzyme cleavage involve biohazardous and time-consuming operations, which cannot meet the demand for rapid, eco-friendly, and portable detection, which are detrimental to the development of multiplex PEC sensors toward portability. Herein, we report a pioneer work on IR-driven "four-to-one" multisignal conditioning to facile reconfigure electrode interface for multitarget detection via photoelectrochemical/photothermal dual mode.
View Article and Find Full Text PDFCureus
December 2024
Department of Ophthalmology, Xi'an No. 3 Hospital, the Affiliated Hospital of Northwest University, Xi'an, CHN.
Choroidal nevus is the most common intraocular tumor, and most cases are benign and have no symptoms. However, choroidal nevus carries a low risk for transformation into melanoma, which is a highly aggressive and deadly cancer. In this case report, we present a male patient with blurred vision in his left eye for six months.
View Article and Find Full Text PDFEnviron Pollut
December 2024
Department of Safety, Health and Environmental Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan. Electronic address:
This is the first study to investigate the possible release of microplastic-derived dissolved organic matter (MP-DOM) in water from three major types of bio-based MPs, namely, polylactic acid (PLA), polyhydroxyalkanoate (PHA) and PLA-PHA mixtures, under ultraviolet (UV) irradiation conditions. At an initial MP concentration of approximately 5 g per liter, the release of MP-DOM from the studied MPs ranged from 1.55-6.
View Article and Find Full Text PDFLight Sci Appl
January 2025
Department of Materials Science and Engineering, City University of Hong Kong, Kowloon, 999077, Hong Kong SAR, China.
Low-dimensional lead-free metal halide perovskites are highly attractive for cutting-edge optoelectronic applications. Herein, we report a class of scandium-based double perovskite crystals comprising antimony dopants that can generate multiexcitonic emissions in the ultraviolet, blue, and yellow spectral regions. Owing to the zero-dimensional nature of the crystal lattice that minimizes energy crosstalk, different excitonic states in the crystals can be selectively excited by ultraviolet light, X-ray irradiation, and mechanical action, enabling dynamic control of steady/transient-state spectral features by modulating the excitation modes.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
December 2024
University of Chicago, Department of Radiology, Chicago, Illinois, United States.
Purpose: High soft-tissue contrast imaging is essential for effective radiotherapy treatment. This could potentially be realized using both megavoltage and kilovoltage x-ray sources available on some therapy treatment systems to perform "MV-kV" dual-energy (DE) computed tomography (CT). However, noisy megavoltage images obtained with existing energy-integrating detectors (EIDs) are a limiting factor for clinical translation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!