A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Monte Carlo-based dosimetric studies of a locally developedTm LDR brachytherapy seed source. | LitMetric

Tm is being explored as a source for applications in brachytherapy. Although it has adequate physical properties, such as a short half-life (128.6 d), high specific activity and a mean photon energy of about 66 keV, it has a drawback of low photon yield (only about six photon emissions/100 beta emissions). The objective of this work is to study the dosimetric characteristics of a locally developedTm brachytherapy seed source using the Monte Carlo-based EGSnrc code system. In this study, we calculate the dose rate constant, air-kerma strength, radial dose function, anisotropic function and 2D dose-rate distributions in water. Separate simulations are carried out by considering the photon (gamma and characteristic x-ray) and beta spectra of the source. For regions close to the source (surface of the source << 0.4 cm), the dose is solely due to direct dose deposition by beta particles. At larger distances (0.4 cm <<10 cm), the dose is due to bremsstrahlung photons produced by beta particles and photon emissions. The calculated value of the dose rate constant is 1.217 ± 0.052 cGy hU. The value ofper mCi is 0.029 ± 0.0009 U mCi. The contributions of the inherent photon emission and the bremsstrahlung photons to the totalare 0.58 and 0.42, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6498/abecf6DOI Listing

Publication Analysis

Top Keywords

monte carlo-based
8
locally developedtm
8
brachytherapy seed
8
seed source
8
source
6
carlo-based dosimetric
4
dosimetric studies
4
studies locally
4
developedtm ldr
4
ldr brachytherapy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!