Amandys® pyrocarbon interposition arthroplasty is intended for widespread arthritis of the wrist. The aim of this study was to assess the clinical, functional, and radiological results of this arthroplasty with a minimum follow-up of 12 months. This retrospective single-center study brought together all osteoarthritis indications that can benefit from an Amandys® arthroplasty. Twenty-one implants were used between January 2011 and October 2018. There were seven cases of distal radius malunion, eight SLAC wrists, two SNAC wrists, two cases of Kienböck's disease at Lichtman's stage 4, and two aftermaths of inflammatory arthritis. Twenty-four percent of patients had previously undergone another type of surgery for this wrist arthritis. Six implants were removed, five early for dislocation and one after 6 years for chronic pain. Thirteen patients were reviewed with an average follow-up of 40.7 months (21-90). The average pain level on a visual analog scale was 3.1/10 (0-7). The mean range motion was 36° flexion (10-60) and 33° extension (15-50). The mean grip strength at the last follow-up was 14.8 kg (2-30) (43% of contralateral). The average QuickDASH and PRWE functional scores were 37.9/100 (0-80) and 29.6/100 (0-83.5), respectively. Amandys® interposition arthroplasty is an interesting alternative to total wrist fusion or total wrist prosthesis for widespread arthritis of the wrist. For the implant to be stable, the capsulo-ligamentous systems must be intact.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.hansur.2021.03.001 | DOI Listing |
J Hand Surg Eur Vol
January 2025
Institut de la main Nantes-Atlantique, Saint-Herblain, France.
Osteoarthritis of the scaphotrapeziotrapezoidal joint is frequent but often pain-free or well tolerated with non-surgical treatment. Surgical options are numerous and none seems to have clear evidence of superiority. In addition to well-established procedures, such as scaphotrapeziotrapezoidal joint arthrodesis, distal scaphoid resection and trapeziectomy, more recent surgical techniques have been reported.
View Article and Find Full Text PDFHand Surg Rehabil
December 2024
Institut de la Main Nantes Atlantique, Boulevard Charles-Gautier, 44800 Saint-Herblain, France.
Objective: We present long-term results for the Pyrocardan®, a pyrocarbon trapeziometacarpal interposition implant used for the treatment of osteoarthritis of the thumb.
Methods: Between March 2009 and May 2013, 199 arthroplasties were performed in a single hand center, in 184 patients by 6 hand surgeons. 107 implants were followed up for a mean 137 months (range, 120 to 168 months).
Hand Surg Rehabil
December 2024
Institut Main Nantes Atlantique, Boulevard Charles-Gautier, 44800 Saint-Herblain, France. Electronic address:
Introduction: Destruction of the metacarpophalangeal joint can result in disabling pain and stiffness. Several therapeutic options are available, including pyrocarbon interposition implants. The primary endpoint of this study was assessment of clinical and radiographic outcomes in 34 patients treated with HAPY® pyrocarbon interposition implants (Tornier, Grenoble, France) with a minimum follow-up of 3 years.
View Article and Find Full Text PDFJ Hand Surg Glob Online
November 2024
University of Pittsburgh Medical Center Department of Orthopedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA.
Purpose: Thumb carpometacarpal (CMC) arthritis is the most common arthritis of the hand, with most studies demonstrating little difference in outcomes between various surgical treatment techniques. However, trapeziectomy, followed by ligament reconstruction and tendon interposition (LRTI), remains the technique of choice among hand surgeons in the United States. In 2009, suture suspensionplasty (SS) was first described as a less invasive alternative to LRTI.
View Article and Find Full Text PDFShoulder Elbow
December 2024
Department of Orthopaedic Surgery, AZ Monica, Orthoca, Antwerp, Belgium.
Radiocapitellar arthroplasty has been shown to improve pain and function in patients with a degenerative joint. Due to problems with the loosening of the radial head component, one of the few available systems was removed from the global market. This offered specific challenges in terms of treatment strategies when one or both components of a system that is no longer available fail.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!