Silicone-hydrogel (SiH) contact lenses are frequently used as a bandage after anterior segment surgical procedures. Several types of lenses may exhibit clinical performances with different characteristics. This study aims to evaluate the efficacy of two SiH contact lenses following corneal crosslinking (CXL). Forty-nine keratoconus patients scheduled for consecutive CXL surgery in both eyes were included in this comparative, double-blind, prospective study. A Balafilcon A (Pure Vision 2 HD, Bausch+Lomb, Rochester, NY, USA) or Lotrafilcon B (Air Optix Aqua, Ciba Vision, Duluth, GA, USA) lens was fitted in a randomised fashion in the eyes at the end of the CXL. Remaining epithelial defect area measured by slitlamp biomicroscopy, subjective level of pain and discomfort with visual analogue scale (VAS) and total number of oral analgesics taken were evaluated and compared at post-operative days 0, 1, 2 and 3. The average epithelial defect size was significantly smaller in the eyes with Lotrafilcon B than the eyes with Balafilcon A at post-operative Day 1 (31.2 ± 4.3 mm and 33.8 ± 5.2 mm, respectively, p < 0.001) and Day 2 (8.2 ± 3.6 mm and 10.5 ± 5.4 mm, respectively, p = 0.039). There was no statistically significant in the average epithelial defect size between the groups at Day 3 (p = 0.859). Re-epithelialisation time was similar in both groups (p = 0.317) There was no statistically significant difference in VAS scores regarding the lens type in any post-operative follow-up. The mean oral analgesic numbers were similar in both groups (p = 0.217). SiH contact lenses can be used as an effective bandage for corneal re-epithelialisation after CXL. The material and features of bandage contact lens used after CXL may affect the corneal re-epithelialisation process. Lotrafilcon B lens showed faster re-epithelialisation at post-operative days 1 and 2 after CXL.

Download full-text PDF

Source
http://dx.doi.org/10.1080/08164622.2021.1878838DOI Listing

Publication Analysis

Top Keywords

contact lenses
12
lenses corneal
8
corneal crosslinking
8
sih contact
8
epithelial defect
8
efficacy silicone-hydrogel
4
silicone-hydrogel bandage
4
bandage contact
4
lenses
4
crosslinking silicone-hydrogel
4

Similar Publications

Purpose: To determine the countrywide prevalence of dry eye disease (DED) at the population level in Spain, and associated risks.

Methods: This was a cross-sectional study based on a telephone survey conducted in 2022. Participants from the general population were selected by sex, age, region, and population of residence to ensure the representativeness of the Spanish population.

View Article and Find Full Text PDF

Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.

Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.

View Article and Find Full Text PDF

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Perovskite-Based Smart Eyeglasses as Noncontact Human-Computer Interaction.

Adv Mater

January 2025

Key Laboratory of Green Printing, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences (ICCAS), Beijing Engineering Research Center of Nanomaterials for Green Printing Technology, Beijing National Laboratory for Molecular Sciences (BNLMS), Beijing, 100080, P. R. China.

More than 70% of human information comes from vision. The eye is one of the most attractive sensing sites to collect biological parameters. However, it is urgent to develop a cost-effective and easy-to-use approach to monitor eyeball information in a minimally invasive way instead of current smart contact lenses or camera-based eyeglasses.

View Article and Find Full Text PDF

Importance: For myopia control to be beneficial, it would be important that the benefit of treatment (slowed eye growth) is not lost because of faster than normal growth (rebound) after discontinuing treatment.

Objective: To determine whether there is a loss of treatment effect (rebound) after discontinuing soft multifocal contact lenses in children with myopia.

Design, Setting, And Participants: The Bifocal Lenses in Nearsighted Kids 2 (BLINK2) cohort study involved children with myopia (aged 11-17 years at BLINK2 baseline) who completed the BLINK Study randomized clinical trial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!