A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dielectric Properties of Human Active Liver, Kidney and Spleen Compared to Those of Respective Inactive Tissues, Porcine Tissues and the Data Provided by a Database in the Frequency Range of 10 Hz to 100 MHz. | LitMetric

Objective: The purpose of this work is to study whether the active state and species of biological tissues can influence changes in their dielectric properties.

Methods: In this paper, the dielectric properties of liver, kidney and spleen tissues from human active, human inactive and animal tissues are measured in the frequency range of 10 Hz to 100 MHz. The four- and two-electrode methods are used to measure dielectric properties at different frequencies. Statistical analysis and the pattern recognition method are used to compare the dielectric properties of human active tissues, human inactive tissues, animal tissues and data provided by the IFAC database.

Results: The results show that the dielectric properties of human active tissues are significantly different from those of human inactive tissues and animal tissues, resulting in a great difference between the dielectric properties provided by the IFAC database and those of human active tissues. The dielectric properties of human active tissues can be identified by the pattern recognition method based on principal component analysis, which further proves that the dielectric properties of human active tissues cannot be replaced.

Conclusion: The dielectric properties of biological tissues are closely related to the activity and species of tissues. The dielectric properties of human active tissues cannot be replaced by those of human cadaver tissues or animal tissues.

Significance: The significance of this study is suggesting that the IFAC database should be updated with the dielectric properties of human active tissues to provide accurate data for bioelectromagnetics research.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2021.3065016DOI Listing

Publication Analysis

Top Keywords

dielectric properties
44
human active
36
properties human
28
active tissues
28
tissues
19
human
13
dielectric
12
inactive tissues
12
tissues human
12
human inactive
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!