Purpose: Defocus blur imposed by positive lenses can induce hyperopia, whereas blur imposed by diffusers induces deprivation myopia. It is unclear whether the retina can distinguish between both conditions when the magnitude of blur is matched.

Methods: Ten emmetropic (average 0.0 ± 0.3 diopters [D]) and 10 subjects with myopia (-2.7 ± 0.9 D; 24 ± 4 years) watched a movie on a large screen (65 inches at 2 meters (m) distance. The movie was presented either unfiltered ("control"), with calculated low-pass filtering equivalent to a defocus of 2.5 D, or with binocular real optical defocus of +2.5 D. Spatial filtering was done in real-time by software written in Visual C++. Axial length was followed with the Lenstar LS-900 with autopositioning system.

Results: Watching unfiltered movies ("control") caused no changes in axial length. In emmetropes, watching movies with calculated defocus caused axial eye elongation (+9.8 ± 7.6 µm) while watching movies with real positive defocus caused shorter eyes (-8.8 ± 9.2 µm; difference between both P < 0.0001). In addition, in myopes, calculated defocus caused longer eyes (+8.4 ± 9.0 µm, P = 0.001). Strikingly, myopic eyes became also longer with positive defocus (+9.1 ± 11.2 µm, P = 0.02). The difference between emmetropic and myopic eyes was highly significant (-8.8 ± 9.2 µm vs. +9.1 ± 11.2 µm, respectively, P = 0.001).

Conclusions: (1) In emmetropic human subjects, the retina is able to distinguish between real positive defocus and calculated defocus even when the modulation transfer function was matched, (2) in myopic eyes, the retina no longer distinguishes between both conditions because the eyes became longer in both cases. Results suggest that the retina in a myopic eye has reduced ability to detect positive defocus.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7960797PMC
http://dx.doi.org/10.1167/iovs.62.3.14DOI Listing

Publication Analysis

Top Keywords

positive defocus
20
calculated defocus
12
defocus caused
12
myopic eyes
12
defocus
11
emmetropic myopic
8
defocus calculated
8
blur imposed
8
retina distinguish
8
axial length
8

Similar Publications

Purpose: This study compares the functional outcomes of correction using two different types of aberrational extended depth-of-focus (EDOF) intraocular lenses (IOLs).

Material And Methods: The study was conducted in two standardized groups (20 patients, 20 eyes in each group). Patients in group 1 were implanted EDOF IOL I, in group 2 - EDOF IOL II.

View Article and Find Full Text PDF

Background: Thus far, considerable research has been focused on classifying a lesion as benign or malignant. However, there is a requirement for quick depth estimation of a lesion for the accurate clinical staging of the lesion. The lesion could be malignant and quickly grow beneath the skin.

View Article and Find Full Text PDF

Purpose: This study evaluates differences in the visual field performance when wearing the Defocus Incorporated Multiple Segments (DIMS) spectacle lens compared to wearing a conventional single vision (SV) spectacle lens.

Methods: Twenty-one children aged 9-14 years with spherical equivalent refraction (SER) between -1.13D to -4.

View Article and Find Full Text PDF

Purpose: We evaluated through-focus visual performance and accommodative response in young subjects through three segmented multifocal designs for myopia control, mapped on the spatial light modulator of a monocular adaptive optics visual simulator (AOVS), and compared with single vision (SV).

Methods: The segmented multifocal patterns included a 4 mm diameter center distance zone and offset peripheral defocus (MP1), astigmatism and coma (MP2), or a combination (MP3). High-contrast logMAR visual acuity (VA) was measured with monochromatic stimuli (555 nm).

View Article and Find Full Text PDF

Purpose: To assess visual outcomes and stability of lens alignment more than 3 years after implanting either the AT Lisa Tri Toric (Carl Zeiss Meditec) or the Acrysof IQ Restor Toric (Alcon Laboratories, Inc) intraocular lens (IOL).

Methods: Patients who had received either the AT Lisa Tri Toric or the Acrysof IQ Restor Toric IOL were included in the study. The average follow-up period was 5.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!