A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single Center Experience with Endovascular Repair of Acute Thoracoabdominal Aortic Aneurysms. | LitMetric

Single Center Experience with Endovascular Repair of Acute Thoracoabdominal Aortic Aneurysms.

Cardiovasc Intervent Radiol

Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University, 90471, Nuremberg, Germany.

Published: June 2021

Purpose: To investigate feasibility and outcomes of endovascular repair for acute thoracoabdominal aortic aneurysms (TAAA).

Materials And Methods: Data from a single center were retrospectively analyzed. Patients who underwent endovascular repair for acute TAAA between January 2010 and April 2020 were included. Perioperative and mid-term follow-up outcomes were analyzed. Survival, freedom from reintervention, and target vessel patency were calculated by Kaplan-Meier analysis.

Results: A total of 30 patients (18 men, 67.5 ± 6.9 years) underwent endovascular repair for acute symptomatic (n = 15) or contained ruptured (n = 15) TAAA. An off-the-shelf four-branched stent-graft (T-Branch) was used in 19 (63.3%) patients, a custom-made device (CMD) with expedite order in 5 (16.7%) patients, a CMD with short anticipated delivery time in 3 (10.0%) patients, and a CMD available in the hospital in 3 (10.0%) patients. Technical success was 90.0% (n = 27). Thirty-day mortality was 10% (n = 3). There was no complete persistent paraplegia, but one (3.3%) patient suffered permanent limb weakness. Estimated survival at 1 and 2 years was 86.3% ± 6.4%, and 82.3% ± 7.2%, respectively. Estimated freedom from reintervention at 1 and 2 years was 81.4% ± 7.6% and 73% ± 8.8%. Estimated target vessel patency at 1 and 2 years was 96.6% ± 2% and 92.6% ± 2.9%.

Conclusion: Endovascular treatment of acute TAAA in this selected group of patients was associated with low early mortality and excellent mid-term survival. The off-the-shelf stent-graft option (T-Branch) was used in the majority of patients. Endovascular repair should be considered the first option for suitable acute TAAA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7939448PMC
http://dx.doi.org/10.1007/s00270-021-02798-1DOI Listing

Publication Analysis

Top Keywords

endovascular repair
20
repair acute
16
acute taaa
12
single center
8
acute thoracoabdominal
8
thoracoabdominal aortic
8
aortic aneurysms
8
patients
8
underwent endovascular
8
freedom reintervention
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!