The anti-citrillinated protein antibody (ACPA) plays an important role in early diagnosis of rheumatoid arthritis (RA), and is usually detected by using cyclic citrullinated peptide (CCP) as antigen. The ACPA against CCP test is usually performed utilizing enzyme-linked immunosorbent assay (ELISA), but the ELISA is expensive and time-consuming. Here, latex particle-enhanced turbidimetric immunoassay (LTIA) based on CCP-immobilized latex bead was proposed for fast measurements of ACPA of RA patients. CCP-immobilized latex bead was fabricated through three methods, including direct coupling, overall coupling and layer by layer coupling. According to the optimized experiments, layer-by-layer coupling was the best method with advantages of time-saving, simple operation and good repeatability. In addition, a spacer arm of appropriate length between latex beads and CCP could avoid stereoscopic obstacles and make ACPA closer to CCP. The CCP-immobilized latex bead based on layer by layer coupling (CCP-LB-LLC) was used for assembling the homemade kit, which was applied in fast measurements of ACPA through LTIA. The homemade kit possessed a low limit of detection (0.2 U/mL) and an acceptable the batch-to-batch reproducibility. In addition, the homemade kit can be stored at 4 °C for at least one month. When used to detect 20 clinical samples, the results of homemade kit were consistent with commercial ELISA. Furthermore, LTIA based on the homemade kit was simpler and cheaper than ELISA. These results demonstrated that the homemade kit could be useful for diagnosis of RA patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2021.462000 | DOI Listing |
Sci Rep
October 2024
Key Laboratory of Bionic Engineering (Ministry of Education), Jilin University, Changchun, 130022, China.
Many laboratories use two-photon microscopy through commercial suppliers, or homemade designs of considerable complexity. The integrated nature of these systems complicates customization, troubleshooting, and training on the principles of two-photon microscopy. Here, we present "Twinkle": a microscope for Two-photon Imaging in Neuroscience, and Kit for Learning and Education.
View Article and Find Full Text PDFActa Parasitol
December 2024
Clinical Pathology, Faculty of Medicine, Ain Shams University, Cairo, Egypt.
Background: For years, the Kato-Katz (KK) technique has been considered the gold standard for diagnosing schistosomiasis. The aim of this study was to compare the effectiveness of our previously developed gold nanoparticle-based lateral flow test strip (AuNPs-LFTS) for diagnosing active Schistosoma mansoni with that of the commercially available point-of-care Circulating Cathodic Antigen detection (POC-CCA) kit.
Methods: In this study, we collected sixty positive and twenty negative urine samples from patients in endemic hot spots in the Nile Delta, as well as from patients visiting the internal medicine clinic at Theodor Bilharz Research Institute (TBRI).
Viruses
September 2024
Department of Medical Biotechnologies, University of Siena, 53100 Siena, Italy.
Background: Next-generation sequencing (NGS) kits are needed to finalise the transition from Sanger sequencing to NGS in HIV-1 genotypic drug resistance testing.
Materials And Methods: We compared a homemade NGS amplicon-based protocol and the AD4SEQ HIV-1 Solution v2 (AD4SEQ) NGS kit from Arrow Diagnostics for identifying resistance-associated mutations (RAMs) above the 5% threshold in 28 plasma samples where Sanger sequencing previously detected at least one RAM.
Results: The samples had a median 4.
Virol J
August 2024
Department of Microbiology, Shahrekord Branch, Islamic Azad University, Shahrekord, Iran.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!