Three-dimensional ultrasound is a reliable alternative in endovascular aortic repair surveillance.

J Vasc Surg

Department of Vascular Surgery, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.

Published: September 2021

Objective: Three-dimensional ultrasound (3D-US) has already demonstrated improved reproducibility with a high degree of agreement (intermodality variability), reproducibility (interoperator variability), and repeatability (intraoperator variability) compared with conventional two-dimensional ultrasound (2D-US) when estimating the maximum diameter of native abdominal aortic aneurysms (AAAs). The aim of the present study was, in a clinical, multicenter setting, to evaluate the accuracy of 3D-US with aneurysm model quantification software (3D-US abdominal aortic aneurysm [AAA] model) for endovascular aortic aneurysm repair (EVAR) sac diameter assessment vs that of computed tomography angiography (CTA) and 2D-US.

Methods: A total of 182 patients who had undergone EVAR from April 2016 to December 2017 and were compliant with a standardized EVAR surveillance program were enrolled from five different vascular centers (Rigshospitalet, Copenhagen, Denmark; Catharina Ziekenhuis, Eindhoven, Netherlands; L'hospital de la Timone, Paris, France; Cleveland Clinic, Cleveland, Ohio; and The Christ Hospital, Cincinnati, Ohio) in four countries. All image acquisitions were performed at the local sites (ie, 2D-US, 3D-US, CTA). Only the 2D-US and CTA readings were performed both locally and centrally. All images were read centrally by the US and CTA core laboratory. Anonymized image data were read in a randomized and blinded manner.

Results: The sample used to estimate the accuracy of the 3D-US AAA model and 2D-US included 164 patients and 177 patients, respectively. The Bland-Altman analysis revealed that the mean difference between CTA and 3D-US was -2.43 mm (95% confidence interval [CI], -5.20 to 0.14; P = .07) with a lower and upper limit of agreement of -8.9 mm (95% CI, -9.3 to -8.4) and 2.7 mm (95% CI, 2.3-3.2), respectively. For 2D-US and CTA, the mean difference was -3.62 mm (95% CI, -6.14 to -1.10; P = .002), with a lower and upper limit of agreement of -10.3 mm (95% CI, -10.8 to -9.8) and 2.5 mm (95% CI, 2-2.9), respectively.

Conclusions: The 3D-US AAA model showed no significant difference compared with CTA for measuring the anteroposterior diameter, indicating less bias for 3D-US compared with 2D-US. Thus, 3D-US with AAA model software is a viable modality for anteroposterior diameter assessment for surveillance after EVAR.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2021.02.031DOI Listing

Publication Analysis

Top Keywords

3d-us aaa
12
aaa model
12
3d-us
9
three-dimensional ultrasound
8
endovascular aortic
8
abdominal aortic
8
accuracy 3d-us
8
aortic aneurysm
8
diameter assessment
8
2d-us cta
8

Similar Publications

Background: The current management of abdominal aortic aneurysm (AAA) hinges upon assessing diameter using ultrasound (US). Diameter reproducibility with conventional two-dimensional ultrasound (2D-US) is challenging and requires experienced operators. A novel automatic three-dimensional ultrasound (3D-US) system enables on-cart software-assisted diameter estimation (3D-SAUS), potentially facilitating more precise diameter measurements than 2D-US.

View Article and Find Full Text PDF

High frame rate ultrasound (US) imaging techniques in 3D are promising tools for capturing abdominal aortic aneurysms (AAAs) over time, however, with the limited number of channel-to-element connections current footprints are small, which limits the field of view. Moreover, the maximal steering angle of the ultrasound beams in transmit and the maximal receptance angle in receive are insufficient for capturing the curvy shape of the AAA. Therefore, an approach is needed towards large arrays.

View Article and Find Full Text PDF

Background: Three-dimensional ultrasound (3D-US) and computed tomography (CT) have proven abdominal aortic aneurysm (AAA) volume a more sensitive measure of growth than diameter. This proof-of-concept study aimed to investigate the clinical applicability of two-dimensional ultrasound and 3D-US for AAA diameter and volume growth pattern evaluation.

Methods: AAA patients with at least three follow-ups within a minimum of 24 months were included prospectively and consecutively from the COpenhagen Aneurysms CoHort (COACH).

View Article and Find Full Text PDF

Full-Volume Assessment of Abdominal Aortic Aneurysm by Improved-Field-of-View 3-D Ultrasound Performs Comparably to Computed Tomographic Angiography.

Ultrasound Med Biol

February 2022

Department of Vascular Surgery, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark; Copenhagen Academy for Medical Education and Simulation (CAMES), Capital Region of Denmark, Copenhagen, Denmark.

Three-dimensional ultrasound (US) of abdominal aortic aneurysms (AAAs) is limited by the field-of-view of the 3D-US transducer. To obtain an extended field-of-view (XFoV), two transducer navigation system-assisted US protocols have been developed: XFoV-2D and XFoV-3D. In this study, the XFoV US protocols were compared with the currently available 3D-US protocol with standard field-of-view (FoV-st) and the established gold standard, computed tomography angiography (CTA).

View Article and Find Full Text PDF

Background: Profiling is a new method based on three-dimensional ultrasound (3D-US) allowing for direct comparison of baseline and follow-up diameters along the AAA length. This study aimed to evaluate the feasibility of profiling to visualize AAA changes at submaximum diameters, and to categorize the growth profiles.

Methods: This is a retrospective analysis of prospectively and consecutively included patients under AAA surveillance at a tertiary referral center.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!